3 results (0.003 seconds)

CVSS: 9.8EPSS: 5%CPEs: 2EXPL: 0

The affected product is vulnerable to the handling of serialized data. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information. El producto afectado es vulnerable al manejo de datos serializados. El problema resulta de la falta de una comprobación apropiada de los datos suministrados por el usuario, lo que puede resultar en una deserialización de datos no confiables en Ignition 8 Gateway (versiones anteriores a 8.0.10) y Ignition 7 Gateway (versiones anteriores a la 7.9.14), permitiendo a un atacante obtener información confidencial This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is not required to exploit this vulnerability. The specific flaw exists with the handling of serialized data. • https://www.us-cert.gov/ics/advisories/icsa-20-147-01 • CWE-502: Deserialization of Untrusted Data •

CVSS: 9.8EPSS: 82%CPEs: 2EXPL: 0

The affected product lacks proper validation of user-supplied data, which can result in deserialization of untrusted data on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information. El producto afectado carece de una comprobación apropiada de los datos suministrados por el usuario, lo que puede dar resultar en una deserialización de datos no confiables en Ignition 8 Gateway (versiones anteriores a 8.0.10) y Ignition 7 Gateway (versiones anteriores a la 7.9.14), permitiendo a un atacante obtener información confidencial This vulnerability allows remote attackers to execute arbitrary code on affected installations of Inductive Automation Ignition. Authentication is not required to exploit this vulnerability. The specific flaw exists with the handling of project diffs. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this to execute code in the context of SYSTEM. • http://packetstormsecurity.com/files/158226/Inductive-Automation-Ignition-Remote-Code-Execution.html https://www.us-cert.gov/ics/advisories/icsa-20-147-01 • CWE-502: Deserialization of Untrusted Data •

CVSS: 7.5EPSS: 84%CPEs: 2EXPL: 0

The affected product lacks proper authentication required to query the server on the Ignition 8 Gateway (versions prior to 8.0.10) and Ignition 7 Gateway (versions prior to 7.9.14), allowing an attacker to obtain sensitive information. El producto afectado carece de una autenticación apropiada requerida para consultar el servidor en Ignition 8 Gateway (versiones anteriores a 8.0.10) y Ignition 7 Gateway (versiones anteriores a la 7.9.14), permitiendo a un atacante obtener información confidencial This vulnerability allows remote attackers to disclose sensitive information on affected installations of Inductive Automation Ignition. Authentication is not required to exploit this vulnerability. The specific flaw exists within the getDiffs method of the com.inductiveautomation.ignition.gateway.servlets.gateway.functions.ProjectDownload class. The issue results from the lack of proper authentication required to query to server. An attacker can leverage this in conjunction with other vulnerabilities to execute code in the context of SYSTEM. • http://packetstormsecurity.com/files/158226/Inductive-Automation-Ignition-Remote-Code-Execution.html https://www.us-cert.gov/ics/advisories/icsa-20-147-01 • CWE-306: Missing Authentication for Critical Function •