CVSS: 9.8EPSS: 0%CPEs: 20EXPL: 0

Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer versiones 21 y posteriores, y RSLogix 5000 versiones 16 hasta 20, usan una clave para verificar que los controladores Logix se estén comunicando con Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer versiones 21 y posteriores y RSLogix 5000: Versiones 16 hasta 20, son vulnerables porque un atacante no autenticado podría pasar por alto este mecanismo de comprobación y autenticarse con Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550 , 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800 • https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03 • CWE-522: Insufficiently Protected Credentials •

CVSS: 4.3EPSS: 0%CPEs: 3EXPL: 0

Rockwell Automation Logix Designer Studio 5000 Versions 32.00, 32.01, and 32.02 vulnerable to an xml external entity (XXE) vulnerability, which may allow an attacker to view hostnames or other resources from the program. Rockwell Automation Logix Designer Studio 5000 Versiones 32.00, 32.01 y 32.02, es susceptible a una vulnerabilidad de tipo xml external entity (XXE), que puede permitir a un atacante visualizar nombres de host u otros recursos del programa This vulnerability allows remote attackers to disclose sensitive information on affected installations of Rockwell Automation Studio 5000. Authentication is not required to exploit this vulnerability. The specific flaw exists within the parsing of AML files. Due to the improper restriction of XML External Entity (XXE) references, a specially crafted document specifying a URI causes the XML parser to access the URI and embed the contents back into the XML document for further processing. An attacker can leverage this vulnerability to disclose information in the context of the current process. • https://us-cert.cisa.gov/ics/advisories/icsa-20-191-02 • CWE-611: Improper Restriction of XML External Entity Reference •

CVSS: 8.2EPSS: 0%CPEs: 7EXPL: 0

Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable.The EDS subsystem does not provide adequate input sanitation, which may allow an attacker to craft specialized EDS files to inject SQL queries and manipulate the database storing the EDS files. This can lead to denial-of-service conditions. Productos que usan EDS Subsystem: versión 28.0.1 y anteriores (software FactoryTalk Linx (anteriormente llamado RSLinx Enterprise): versiones 6.00, 6.10 y 6.11, RSLinx Classic: versión 4.11.00 y anteriores, software RSNetWorx: versión 28.00.00 y anteriores, software Studio 5000 Logix Designer: versión 32 y anteriores) son vulnerables. El EDS Subsystem no proporciona un saneamiento de entrada adecuado, lo que puede permitir a un atacante diseñar archivos EDS especializados para inyectar consultas SQL y manipular la base de datos que almacena los archivos EDS. Esto puede conllevar a condiciones de denegación de servicio. • https://www.us-cert.gov/ics/advisories/icsa-20-140-01 • CWE-89: Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection') •

CVSS: 5.5EPSS: 0%CPEs: 7EXPL: 0

Products that use EDS Subsystem: Version 28.0.1 and prior (FactoryTalk Linx software (Previously called RSLinx Enterprise): Versions 6.00, 6.10, and 6.11, RSLinx Classic: Version 4.11.00 and prior, RSNetWorx software: Version 28.00.00 and prior, Studio 5000 Logix Designer software: Version 32 and prior) is vulnerable. A memory corruption vulnerability exists in the algorithm that matches square brackets in the EDS subsystem. This may allow an attacker to craft specialized EDS files to crash the EDSParser COM object, leading to denial-of-service conditions. Productos que usan EDS Subsystem: versión 28.0.1 y anteriores (software FactoryTalk Linx (anteriormente llamado RSLinx Enterprise): versiones 6.00, 6.10 y 6.11, RSLinx Classic: versión 4.11.00 y anteriores, software RSNetWorx: versión 28.00.00 y anteriores , software Studio 5000 Logix Designer: versión 32 y anteriores), es vulnerable. Se presenta una vulnerabilidad de corrupción de memoria en el algoritmo que coincide con los corchetes en el subsistema EDS. • https://www.us-cert.gov/ics/advisories/icsa-20-140-01 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-787: Out-of-bounds Write •