2 results (0.004 seconds)

CVSS: 8.3EPSS: 0%CPEs: 1EXPL: 0

A CWE-295: Improper Certificate Validation vulnerability exists that could cause the CAE software to give wrong data to end users when using CAE to configure devices. Additionally, credentials could leak which would enable an attacker the ability to log into the configuration tool and compromise other devices in the network. Affected Products: EcoStruxureâ„¢ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2) • https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf • CWE-295: Improper Certificate Validation •

CVSS: 8.1EPSS: 0%CPEs: 1EXPL: 0

A CWE-290: Authentication Bypass by Spoofing vulnerability exists that could cause legitimate users to be locked out of devices or facilitate backdoor account creation by spoofing a device on the local network. Affected Products: EcoStruxureâ„¢ Cybersecurity Admin Expert (CAE) (Versions prior to 2.2) • https://download.schneider-electric.com/files?p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-165-08_Cybersecurity_Admin_Expert_Security_Notification.pdf • CWE-290: Authentication Bypass by Spoofing •