CVE-2024-8306
https://notcve.org/view.php?id=CVE-2024-8306
11 Sep 2024 — CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized access, loss of confidentiality, integrity and availability of the workstation when non-admin authenticated user tries to perform privilege escalation by tampering with the binaries. CWE-269: Improper Privilege Management vulnerability exists that could cause unauthorized access, loss of confidentiality, integrity and availability of the workstation when non-admin authenticated user tries to perform privilege escalatio... • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-254-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-254-01.pdf • CWE-269: Improper Privilege Management •

CVE-2022-2988
https://notcve.org/view.php?id=CVE-2022-2988
30 Jan 2023 — A CWE-787: Out-of-bounds Write vulnerability exists that could cause sensitive information leakage when accessing a malicious web page from the commissioning software. Affected Products: SoMachine HVAC (Versions prior to V2.1.0), EcoStruxure Machine Expert – HVAC (Versions prior to V1.4.0) Existe una vulnerabilidad CWE-787: escritura fuera de los límites que podría provocar una fuga de información confidencial al acceder a una página web maliciosa desde el software de puesta en marcha. Productos afectados: ... • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-01_EcoStruxure_Machine_Expert_Machine_HVAC_Security_Notification.pdf • CWE-787: Out-of-bounds Write •

CVE-2021-22704
https://notcve.org/view.php?id=CVE-2021-22704
02 Sep 2021 — A CWE-22: Improper Limitation of a Pathname to a Restricted Directory vulnerability exists in Harmony/HMI Products Configured by Vijeo Designer (all versions prior to V6.2 SP11 ), Vijeo Designer Basic (all versions prior to V1.2), or EcoStruxure Machine Expert (all versions prior to V2.0) that could cause a Denial of Service or unauthorized access to system information when connecting to the Harmony HMI over FTP. Una CWE-22: Una vulnerabilidad de Limitación Inapropiada de un Nombre de Ruta a un Directorio R... • http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-222-01 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVE-2021-22705
https://notcve.org/view.php?id=CVE-2021-22705
26 May 2021 — Improper Restriction of Operations within the Bounds of a Memory Buffer vulnerability exists that could cause denial of service or unauthorized access to system information when interacting directly with a driver installed by Vijeo Designer or EcoStruxure Machine Expert Se presenta una vulnerabilidad de Restricción Inapropiada de Operaciones dentro de los límites de un búfer de la memoria, que podría causar una denegación de servicio o acceso no autorizado a la información del sistema interactuando directam... • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-02 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVE-2020-7488
https://notcve.org/view.php?id=CVE-2020-7488
22 Apr 2020 — A CWE-319: Cleartext Transmission of Sensitive Information vulnerability exists which could leak sensitive information transmitted between the software and the Modicon M218, M241, M251, and M258 controllers. CWE-319: Hay una vulnerabilidad de Transmisión de Información Confidencial en Texto Sin Cifrar que podría filtrar información confidencial transmitida entre el software y los controladores Modicon M218, M241, M251 y M258. • https://www.se.com/ww/en/download/document/SEVD-2020-105-02 • CWE-319: Cleartext Transmission of Sensitive Information •

CVE-2020-7487
https://notcve.org/view.php?id=CVE-2020-7487
22 Apr 2020 — A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists which could allow the attacker to execute malicious code on the Modicon M218, M241, M251, and M258 controllers. CWE-345: Existe una vulnerabilidad de Verificación Insuficiente de la Autenticidad de Datos, lo que podría permitir al atacante ejecutar código malicioso en los controladores Modicon M218, M241, M251 y M258. • https://www.se.com/ww/en/download/document/SEVD-2020-105-02 • CWE-345: Insufficient Verification of Data Authenticity •

CVE-2020-7489
https://notcve.org/view.php?id=CVE-2020-7489
22 Apr 2020 — A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') vulnerability exists on EcoStruxure Machine Expert – Basic or SoMachine Basic programming software (versions in security notification). The result of this vulnerability, DLL substitution, could allow the transference of malicious code to the controller. A CWE-74: Hay una vulnerabilidad de Neutralización Inapropiada de Elementos Especiales en una Salida Utilizada por un Componente Descendente ('Inject... • https://www.se.com/ww/en/download/document/SEVD-2020-105-01 • CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') •