CVE-2024-8933
https://notcve.org/view.php?id=CVE-2024-8933
CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause retrieval of password hash that could lead to denial of service and loss of confidentiality and integrity of controllers. To be successful, the attacker needs to inject themself inside the logical network while a valid user uploads or downloads a project file into the controller. • https://download.schneider-electric.com/doc/SEVD-2024-317-02/SEVD-2024-317-02.pdf • CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel •
CVE-2024-5056
https://notcve.org/view.php?id=CVE-2024-5056
CWE-552: Files or Directories Accessible to External Parties vulnerability exists which may prevent user to update the device firmware and prevent proper behavior of the webserver when specific files or directories are removed from the filesystem. CWE-552: Existe una vulnerabilidad de archivos o directorios accesibles a terceros que puede impedir que el usuario actualice el firmware del dispositivo e impedir el comportamiento adecuado del servidor web cuando se eliminan archivos o directorios específicos del sistema de archivos. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-163-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-163-01.pdf • CWE-552: Files or Directories Accessible to External Parties •
CVE-2023-25620
https://notcve.org/view.php?id=CVE-2023-25620
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when a malicious project file is loaded onto the controller by an authenticated user. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-05.pdf • CWE-754: Improper Check for Unusual or Exceptional Conditions •
CVE-2023-25619
https://notcve.org/view.php?id=CVE-2023-25619
A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when communicating over the Modbus TCP protocol. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-05.pdf • CWE-754: Improper Check for Unusual or Exceptional Conditions •
CVE-2021-22786
https://notcve.org/view.php?id=CVE-2021-22786
A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-221-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-221-04-Modicon_Controllers_Ethernet_Modules_Security_Notification.pdf • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •