5 results (0.007 seconds)

CVSS: 7.5EPSS: 0%CPEs: 28EXPL: 0

A CWE-269: Improper Privilege Management vulnerability exists that could cause a denial of service of the Ethernet communication of the controller when sending a specific request over SNMP. Affected products: Modicon M340 CPUs(BMXP34* versions prior to V3.40), Modicon M340 X80 Ethernet Communication modules:BMXNOE0100 (H), BMXNOE0110 (H), BMXNOR0200H RTU(BMXNOE* all versions)(BMXNOR* versions prior to v1.7 IR24) Existe una vulnerabilidad CWE-269: Gestión de privilegios inadecuada que podría provocar una Denegación de Servicio (DoS) de la comunicación Ethernet del controlador al enviar una solicitud específica a través de SNMP. Productos afectados: CPU Modicon M340 (versiones BMXP34* anteriores a V3.40), módulos de comunicación Ethernet Modicon M340 X80: BMXNOE0100 (H), BMXNOE0110 (H), BMXNOR0200H RTU (BMXNOE* todas las versiones) (versiones BMXNOR* anteriores a v1. 7IR24) • https://www.se.com/us/en/download/document/SEVD-2022-102-02 • CWE-269: Improper Privilege Management •

CVSS: 5.4EPSS: 0%CPEs: 22EXPL: 0

Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser. Cross-Site Scripting (XSS) reflejado (no persistente) permite que un atacante manipule una URL específica, que contiene JavaScript que se ejecutará en el navegador del cliente PLC de Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H o BMXP342030H. • https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 5.5EPSS: 0%CPEs: 22EXPL: 0

Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page. La inclusión de archivos remotos permite que un atacante manipule una URL específica que referencia al servidor web PLC de Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H o BMXP342030H, de Schneider Electric, el cual, una vez lanzado, resultará en la redirección del navegador a un archivo remoto mediante un script de Java cargado con la página web. • https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02 • CWE-20: Improper Input Validation CWE-98: Improper Control of Filename for Include/Require Statement in PHP Program ('PHP Remote File Inclusion') •

CVSS: 7.8EPSS: 0%CPEs: 30EXPL: 0

A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover. Se ha descubierto un problema de agotamiento de recursos en Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H y BMXP342030H. Un atacante remoto podría enviar un conjunto de paquetes manipulados al PLC para congelarlo, lo que requeriría que el operador presionase físicamente el botón reset en el PLC para recuperarlo. • http://www.securityfocus.com/bid/96414 https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03 https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02 • CWE-400: Uncontrolled Resource Consumption •

CVSS: 10.0EPSS: 0%CPEs: 146EXPL: 0

Directory traversal vulnerability in SchneiderWEB on Schneider Electric Modicon PLC Ethernet modules 140CPU65x Exec before 5.5, 140NOC78x Exec before 1.62, 140NOE77x Exec before 6.2, BMXNOC0401 before 2.05, BMXNOE0100 before 2.9, BMXNOE0110x Exec before 6.0, TSXETC101 Exec before 2.04, TSXETY4103x Exec before 5.7, TSXETY5103x Exec before 5.9, TSXP57x ETYPort Exec before 5.7, and TSXP57x Ethernet Copro Exec before 5.5 allows remote attackers to visit arbitrary resources via a crafted HTTP request. Vulnerabilidad de salto de directorio en SchneiderWEB en los módulos Schneider Electric Modicon PLC Ethernet 140CPU65x Exec anterior a 5.5, 140NOC78x Exec anterior a 1.62, 140NOE77x Exec anterior a 6.2, BMXNOC0401 anterior a 2.05, BMXNOE0100 anterior a 2.9, BMXNOE0110x Exec anterior a 6.0, TSXETC101 Exec anterior a 2.04, TSXETY4103x Exec anterior a 5.7, TSXETY5103x Exec anterior a 5.9, TSXP57x ETYPort Exec anterior a 5.7, y TSXP57x Ethernet Copro Exec anterior a 5.5 permite a atacantes remotos visitar recursos arbitrarios a través de una solicitud HTTP manipulada. • http://download.schneider-electric.com/files?p_Reference=SEVD-2014-260-01&p_EnDocType=Software%20-%20Updates&p_File_Id=608959359&p_File_Name=SEVD-2014-260-01.pdf http://www.securityfocus.com/bid/70193 https://ics-cert.us-cert.gov/advisories/ICSA-14-273-01 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •