CVSS: 6.5EPSS: 0%CPEs: 16EXPL: 0

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when a malicious project file is loaded onto the controller by an authenticated user. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-05.pdf • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 14EXPL: 0

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when communicating over the Modbus TCP protocol. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-05.pdf • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 9.8EPSS: 0%CPEs: 6EXPL: 0

A CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), reflective DLL, vulnerability exists in EcoStruxure Control Expert (all versions prior to 14.1 Hot Fix), Unity Pro (all versions), Modicon M340 (all versions prior to V3.20), Modicon M580 (all versions prior to V3.10), which, if exploited, could allow attackers to transfer malicious code to the controller. Una CWE-74: Una Neutralización Inapropiada de Elementos Especiales en la Salida Usada por un Componente Aguas Abajo ("Inyection"), una DLL reflexiva, la vulnerabilidad se presenta en EcoStruxure Control Expert (todas las versiones anteriores a 14.1 Hot Fix), Unity Pro (todas las versiones), Modicon M340 (todas las versiones anteriores a V3.20), Modicon M580 (todas las versiones anteriores a V3.10), que, si es explotada, podría permitir a atacantes transferir códigos maliciosos hacia el controlador. • http://www.se.com/ww/en/download/document/SEVD-2020-080-01 • CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') •

CVSS: 7.5EPSS: 0%CPEs: 60EXPL: 0

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service when reading data with invalid index using Modbus TCP. CWE-754: Existe una vulnerabilidad de Comprobación Inapropiada de Condiciones Inusuales o Excepcionales en Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (véase la notificación de seguridad para versiones específicas) que podría causar una Denegación de Servicio cuando se leen datos con índice no válido usando Modbus TCP. • https://www.se.com/ww/en/download/document/SEVD-2019-344-01 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 60EXPL: 0

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists in Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (see security notification for specific versions) which could cause a Denial of Service of the controller when reading specific memory blocks using Modbus TCP. CWE-754: Hay una vulnerabilidad de Comprobación Inapropiada de Condiciones Inusuales o Excepcionales en Modicon M580, Modicon M340, Modicon Quantum, Modicon Premium (véase la notificación de seguridad para versiones específicas) que podría causar una Denegación de Servicio del controlador cuando se leen bloques de memoria específicos usando Modbus TCP. • https://www.se.com/ww/en/download/document/SEVD-2019-344-01 https://www.us-cert.gov/ics/advisories/icsa-20-016-01 • CWE-754: Improper Check for Unusual or Exceptional Conditions •