59 results (0.006 seconds)

CVSS: 8.1EPSS: 0%CPEs: 1EXPL: 0

CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability exists that could cause a denial of service and loss of confidentiality, integrity of controllers when conducting a Man in the Middle attack. CWE-924: Existe una vulnerabilidad en la aplicación inadecuada de la integridad de los mensajes durante la transmisión en un canal de comunicación que podría causar una denegación de servicio y pérdida de confidencialidad e integridad de los controladores al realizar un ataque Man in the Middle. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2024-044-01.pdf • CWE-924: Improper Enforcement of Message Integrity During Transmission in a Communication Channel •

CVSS: 6.5EPSS: 0%CPEs: 16EXPL: 0

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when a malicious project file is loaded onto the controller by an authenticated user. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-05.pdf • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 14EXPL: 0

A CWE-754: Improper Check for Unusual or Exceptional Conditions vulnerability exists that could cause denial of service of the controller when communicating over the Modbus TCP protocol. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-101-05&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-101-05.pdf • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.5EPSS: 0%CPEs: 82EXPL: 0

A CWE-200: Information Exposure vulnerability exists that could cause the exposure of sensitive information stored on the memory of the controller when communicating over the Modbus TCP protocol. Affected Products: Modicon M340 CPU (part numbers BMXP34*) (Versions prior to V3.30), Modicon M580 CPU (part numbers BMEP* and BMEH*) (Versions prior to SV3.20), Modicon MC80 (BMKC80) (Versions prior to V1.6), Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) (All Versions), Modicon Momentum MDI (171CBU*) (Versions prior to V2.3), Legacy Modicon Quantum (All Versions) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-221-04&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2022-221-04-Modicon_Controllers_Ethernet_Modules_Security_Notification.pdf • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVSS: 9.8EPSS: 0%CPEs: 72EXPL: 0

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause execution of unauthorized Modbus functions on the controller when hijacking an authenticated Modbus session. Affected Products: EcoStruxure Control Expert (All Versions), EcoStruxure Process Expert (All Versions), Modicon M340 CPU - part numbers BMXP34* (All Versions), Modicon M580 CPU - part numbers BMEP* and BMEH* (All Versions), Modicon M580 CPU Safety - part numbers BMEP58*S and BMEH58*S (All Versions) • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-06&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-010-06_Modicon_Controllers_Security_Notification.pdf • CWE-294: Authentication Bypass by Capture-replay •