3 results (0.004 seconds)

CVSS: 5.5EPSS: 0%CPEs: 2EXPL: 0

A CWE-611: Improper Restriction of XML External Entity Reference vulnerability exists that could cause unauthorized read access to the file system when a malicious configuration file is loaded on to the software by a local user. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-129-01.pdf • CWE-611: Improper Restriction of XML External Entity Reference •

CVSS: 9.3EPSS: 11%CPEs: 21EXPL: 2

Multiple stack-based buffer overflows in ModbusDrv.exe in Schneider Electric Modbus Serial Driver 1.10 through 3.2 allow remote attackers to execute arbitrary code via a large buffer-size value in a Modbus Application Header. Múltiples desbordamientos de buffer basado en pila en ModbusDrv.exe en Schneider Electric Modbus Serial Driver 1.10 hasta 3.2 permiten a atacantes remotos ejecutar código arbitrario a través de un valor de tamaño de buffer grande en Modbus Application Header. SEIG Modbus version 3.4 suffers from a remote code execution vulnerability. • https://www.exploit-db.com/exploits/45219 https://www.exploit-db.com/exploits/45220 http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202013-070-01 http://ics-cert.us-cert.gov/advisories/ICSA-14-086-01 http://www.securityfocus.com/bid/66500 • CWE-787: Out-of-bounds Write •

CVSS: 6.9EPSS: 19%CPEs: 6EXPL: 0

Stack-based buffer overflow in the C++ sample client in Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35, and TLXCDLFOFS33 - 3.35 allows local users to gain privileges via vectors involving a malformed configuration file. Desbordamiento de buffer basado en pila en el cliente C++ de ejemplo en Schneider Electric OPC Factory Server (OFS) TLXCDSUOFS33 - 3.35, TLXCDSTOFS33 - 3.35, TLXCDLUOFS33 - 3.35, TLXCDLTOFS33 - 3.35 y TLXCDLFOFS33 - 3.35 permite a usuarios locales ganar privilegios a través de vectores involucrando un archivo de configuración malformado. This vulnerability allows attackers to execute arbitrary code on vulnerable installations of Schneider Electric OFS Client. User interaction is required to exploit this vulnerability in that the target must load a malicious file. The specific flaw exists within the parsing of the configuration file. A crafted configuration file will result in an exploitable stack buffer overflow. • http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-031-01 http://ics-cert.us-cert.gov/advisories/ICSA-14-058-02 http://www.securityfocus.com/bid/65871 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •