CVE-2023-1049 – Schneider Electric EcoStruxure Operator Terminal Expert VXDZ File Parsing Code Injection Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2023-1049
A CWE-94: Improper Control of Generation of Code ('Code Injection') vulnerability exists that could cause execution of malicious code when an unsuspicious user loads a project file from the local filesystem into the HMI. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric EcoStruxure Operator Terminal Expert. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of of VXDZ files while in simulation mode. When parsing name:value pairs in configuation data, the process does not properly validate a user-supplied string before executing it as code. An attacker can leverage this vulnerability to execute code in the context of the current user. • https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-164-01&p_enDocType=Security+and+Safety+Notice&p_File_Name=SEVD-2023-164-01.pdf • CWE-94: Improper Control of Generation of Code ('Code Injection') •
CVE-2022-41666
https://notcve.org/view.php?id=CVE-2022-41666
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). Existe una vulnerabilidad CWE-347: Verificación Inadecuada de Firma Criptográfica que permite a adversarios con privilegios de usuario local cargar una DLL maliciosa que podría conducir a la ejecución de código malicioso. Productos afectados: EcoStruxure Operator Terminal Expert (V3.3 Hotfix 1 o anterior), Pro-face BLUE (V3.3 Hotfix 1 o anterior). • https://www.se.com/ww/en/download/document/SEVD-2022-284-01 • CWE-347: Improper Verification of Cryptographic Signature •
CVE-2022-41669
https://notcve.org/view.php?id=CVE-2022-41669
A CWE-347: Improper Verification of Cryptographic Signature vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load a malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). Existe una vulnerabilidad CWE-347: Verificación Inadecuada de Firma Criptográfica en el componente SGIUtility que permite a adversarios con privilegios de usuario local cargar una DLL maliciosa que podría resultar en la ejecución de código malicioso. Productos afectados: EcoStruxure Operator Terminal Expert (V3.3 Hotfix 1 o anterior), Pro-face BLUE (V3.3 Hotfix 1 o anterior). • https://www.se.com/ww/en/download/document/SEVD-2022-284-01 • CWE-347: Improper Verification of Cryptographic Signature •
CVE-2022-41667
https://notcve.org/view.php?id=CVE-2022-41667
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists that allows adversaries with local user privileges to load a malicious DLL which could lead to execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). Existe una vulnerabilidad CWE-22: Limitación Inadecuada de un Nombre de Ruta a un Directorio Restringido ("Path Traversal") que permite a adversarios con privilegios de usuario local cargar una DLL maliciosa que podría conducir a la ejecución de código malicioso. Productos afectados: EcoStruxure Operator Terminal Expert (V3.3 Hotfix 1 o anterior), Pro-face BLUE (V3.3 Hotfix 1 o anterior). • https://www.se.com/ww/en/download/document/SEVD-2022-284-01 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •
CVE-2022-41670
https://notcve.org/view.php?id=CVE-2022-41670
A CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability exists in the SGIUtility component that allows adversaries with local user privileges to load malicious DLL which could result in execution of malicious code. Affected Products: EcoStruxure Operator Terminal Expert(V3.3 Hotfix 1 or prior), Pro-face BLUE(V3.3 Hotfix1 or prior). Existe una vulnerabilidad CWE-22: Limitación Inadecuada de un Nombre de Ruta a un Directorio Restringido ("Path Traversal") en el componente SGIUtility que permite a adversarios con privilegios de usuario local cargar archivos DLL maliciosos que podrían resultar en la ejecución de código malicioso. Productos afectados: EcoStruxure Operator Terminal Expert (V3.3 Hotfix 1 o anterior), Pro-face BLUE (V3.3 Hotfix 1 o anterior). • https://www.se.com/ww/en/download/document/SEVD-2022-284-01 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •