5 results (0.009 seconds)

CVSS: 7.5EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.40), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint manupulating a specific argument. This could allow an attacker to crash the affected application leading to a denial of service condition Se ha identificado una vulnerabilidad en la variante DNP3 IP del módulo EN100 Ethernet (Todas las versiones), la variante IEC 104 del módulo EN100 Ethernet (Todas las versiones), la variante IEC 61850 del módulo EN100 Ethernet (Todas las versiones anteriores a la versión V4.40), la variante Modbus TCP del módulo EN100 Ethernet (Todas las versiones), la variante PROFINET IO del módulo EN100 Ethernet (Todas las versiones). Las aplicaciones afectadas contienen una vulnerabilidad de corrupción de memoria mientras analizan paquetes HTTP especialmente diseñados para el punto final /txtrace que manupulan un argumento específico. Esto podría permitir a un atacante bloquear la aplicación afectada, provocando una condición de denegación de servicio. • https://cert-portal.siemens.com/productcert/pdf/ssa-865333.pdf • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 6EXPL: 0

A vulnerability has been identified in EN100 Ethernet module DNP3 IP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.37), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). Affected applications contains a memory corruption vulnerability while parsing specially crafted HTTP packets to /txtrace endpoint. This could allow an attacker to crash the affected application leading to a denial of service condition. Se ha identificado una vulnerabilidad en la variante DNP3 IP del módulo EN100 Ethernet (Todas las versiones), la variante IEC 104 del módulo EN100 Ethernet (Todas las versiones), la variante IEC 61850 del módulo EN100 Ethernet (Todas las versiones anteriores a V4.37), la variante Modbus TCP del módulo EN100 Ethernet (Todas las versiones), la variante PROFINET IO del módulo EN100 Ethernet (Todas las versiones). Las aplicaciones afectadas contienen una vulnerabilidad de corrupción de memoria mientras analizan paquetes HTTP especialmente diseñados para el endpoint /txtrace. • https://cert-portal.siemens.com/productcert/pdf/ssa-693555.pdf • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-787: Out-of-bounds Write •

CVSS: 7.5EPSS: 0%CPEs: 10EXPL: 0

A vulnerability has been identified in EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module DNP3 variant (All versions < V1.04), EN100 Ethernet module PROFINET IO variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module IEC 104 variant (All versions < V1.22). The web interface (TCP/80) of affected devices allows an unauthenticated user to upgrade or downgrade the firmware of the device, including to older versions with known vulnerabilities. Se ha identificado una vulnerabilidad en la variante del módulo de Ethernet EN100 IEC 61850 (todas las versiones anteriores a la V4.30), la variante del módulo de Ethernet EN100 DNP3 (todas las versiones anteriores a la V1.04), la variante del módulo de Ethernet EN100 PROFINET IO (todas las versiones), la variante del módulo de Ethernet EN100 Modbus TCP (todas las versiones) y la variante del módulo de Ethernet EN100 IEC 104 (todas las versiones anteriores a la V1.22). La interfaz web (TCP/80) de los dispositivos afectados permite que un usuario no autenticado actualice o degrade el firmware del dispositivo, incluyendo versiones más antiguas con vulnerabilidades conocidas. • https://cert-portal.siemens.com/productcert/pdf/ssa-845879.pdf https://ics-cert.us-cert.gov/advisories/ICSA-18-067-01 https://www.securityfocus.com/bid/103379 • CWE-306: Missing Authentication for Critical Function •

CVSS: 7.5EPSS: 0%CPEs: 17EXPL: 0

A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). The device engineering mechanism allows an unauthenticated remote user to upload a modified device configuration overwriting access authorization passwords. Se ha identificado una vulnerabilidad en Siemens DIGSI 4 (Todas las versiones anteriores a V4.92), EN100 Ethernet module DNP3 variant (Todas las versiones anteriores a V1.05.00), EN100 Ethernet module IEC 104 variant (Todas las versiones), EN100 Ethernet module IEC 61850 variant (Todas las versiones anteriores a V4.30), EN100 Ethernet module Modbus TCP variant (Todas las versiones), EN100 Ethernet module PROFINET IO variant (Todas las versiones). El mecanismo de ingeniería del dispositivo permite que un usuario remoto no autenticado suba una configuración de dispositivo modificada que sobrescriba las contraseñas de autorización de acceso • https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf https://ics-cert.us-cert.gov/advisories/ICSA-18-067-01 • CWE-306: Missing Authentication for Critical Function •

CVSS: 5.3EPSS: 0%CPEs: 17EXPL: 0

A vulnerability has been identified in DIGSI 4 (All versions < V4.92), EN100 Ethernet module DNP3 variant (All versions < V1.05.00), EN100 Ethernet module IEC 104 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions < V4.30), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions), Other SIPROTEC 4 relays (All versions), Other SIPROTEC Compact relays (All versions), SIPROTEC 4 7SD80 (All versions < V4.70), SIPROTEC 4 7SJ61 (All versions < V4.96), SIPROTEC 4 7SJ62 (All versions < V4.96), SIPROTEC 4 7SJ64 (All versions < V4.96), SIPROTEC 4 7SJ66 (All versions < V4.30), SIPROTEC Compact 7SJ80 (All versions < V4.77), SIPROTEC Compact 7SK80 (All versions < V4.77). An attacker with local access to the engineering system or in a privileged network position and able to obtain certain network traffic could possibly reconstruct access authorization passwords. Se ha identificado una vulnerabilidad en Siemens DIGSI 4 (Todas las versiones anteriores a V4.92), EN100 Ethernet module DNP3 variant (Todas las versiones anteriores a V1.05.00), EN100 Ethernet module IEC 104 variant (Todas las versiones), EN100 Ethernet module IEC 61850 variant (Todas las versiones anteriores a V4.30), EN100 Ethernet module Modbus TCP variant (Todas las versiones), EN100 Ethernet module PROFINET IO variant (Todas las versiones), Other SIPROTEC 4 relays (Todas las versiones), Other SIPROTEC Compact relays (Todas las versiones), SIPROTEC 4 7SD80 (Todas las versiones anteriores a V4.70), SIPROTEC 4 7SJ61 (Todas las versiones anteriores a V4.96), SIPROTEC 4 7SJ62 (Todas las versiones anteriores a V4.96), SIPROTEC 4 7SJ64 (Todas las versiones anteriores a V4.96), SIPROTEC 4 7SJ66 (Todas las versiones anteriores a V4.30), SIPROTEC Compact 7SJ80 (Todas las versiones anteriores a V4.77), SIPROTEC Compact 7SK80 (Todas las versiones anteriores a V4.77). Un atacante con acceso local al sistema de ingeniería o en una posición de red privilegiada y capaz de obtener cierto tráfico de red podría reconstruir contraseñas de autorización de acceso • https://cert-portal.siemens.com/productcert/pdf/ssa-203306.pdf https://ics-cert.us-cert.gov/advisories/ICSA-18-067-01 • CWE-326: Inadequate Encryption Strength •