12 results (0.010 seconds)

CVSS: 4.8EPSS: 0%CPEs: 1EXPL: 0

14 May 2024 — A vulnerability has been identified in Parasolid V35.1 (All versions < V35.1.256), Parasolid V36.0 (All versions < V36.0.208), Parasolid V36.1 (All versions < V36.1.173). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted X_T files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. Se ha identificado una vulnerabilidad en Parasolid V35.1 (Todas las versiones < V35.1.256), Parasolid V36.0 (Tod... • https://cert-portal.siemens.com/productcert/html/ssa-046364.html • CWE-476: NULL Pointer Dereference •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

14 May 2024 — A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21578) Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones This vulnerability allows remote attackers to execute arbitrary code on affected installat... • https://cert-portal.siemens.com/productcert/html/ssa-064222.html • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

14 May 2024 — A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21577) Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones This vulnerability allows remote attackers to execute arbitrary code on affected installat... • https://cert-portal.siemens.com/productcert/html/ssa-064222.html • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

14 May 2024 — A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21575) Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones This vulnerability allows remote attackers to execute arbitrary code on affected installat... • https://cert-portal.siemens.com/productcert/html/ssa-064222.html • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

14 May 2024 — A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application contains a type confusion vulnerability while parsing IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21573) Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Simcenter Femap. User interactio... • https://cert-portal.siemens.com/productcert/html/ssa-064222.html • CWE-843: Access of Resource Using Incompatible Type ('Type Confusion') •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

14 May 2024 — A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application contains a type confusion vulnerability while parsing IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21568) Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Simcenter Femap. User interactio... • https://cert-portal.siemens.com/productcert/html/ssa-064222.html • CWE-843: Access of Resource Using Incompatible Type ('Type Confusion') •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

14 May 2024 — A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21566) Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones This vulnerability allows remote attackers to execute arbitrary code on affected installat... • https://cert-portal.siemens.com/productcert/html/ssa-064222.html • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

14 May 2024 — A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21565) Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones This vulnerability allows remote attackers to execute arbitrary code on affected installat... • https://cert-portal.siemens.com/productcert/html/ssa-064222.html • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

14 May 2024 — A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21564) Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones This vulnerability allows remote attackers to execute arbitrary code on affected installat... • https://cert-portal.siemens.com/productcert/html/ssa-064222.html • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

14 May 2024 — A vulnerability has been identified in Simcenter Femap (All versions < V2406). The affected application is vulnerable to memory corruption while parsing specially crafted IGS files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21563) Se ha identificado una vulnerabilidad en el componente PS/IGES Parasolid Translator (todas las versiones This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Simcenter Femap. Us... • https://cert-portal.siemens.com/productcert/html/ssa-064222.html • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •