CVE-2019-0708 – Microsoft Remote Desktop Services Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2019-0708
A remote code execution vulnerability exists in Remote Desktop Services formerly known as Terminal Services when an unauthenticated attacker connects to the target system using RDP and sends specially crafted requests, aka 'Remote Desktop Services Remote Code Execution Vulnerability'. Existe una vulnerabilidad de ejecución remota de código en Remote Desktop Services, anteriormente conocido como Terminal Services, cuando un atacante no autenticado se conecta al sistema de destino mediante RDP y envía peticiones especialmente diseñadas, conocida como 'Remote Desktop Services Remote Code Execution Vulnerability'. The RDP termdd.sys driver improperly handles binds to internal-only channel MS_T120, allowing a malformed Disconnect Provider Indication message to cause a use-after-free. With a controllable data/size remote nonpaged pool spray, an indirect call gadget of the freed channel is used to achieve arbitrary code execution. Microsoft Remote Desktop Services, formerly known as Terminal Service, contains an unspecified vulnerability that allows an unauthenticated attacker to connect to the target system using RDP and send specially crafted requests. • https://www.exploit-db.com/exploits/47120 https://www.exploit-db.com/exploits/46946 https://www.exploit-db.com/exploits/47416 https://www.exploit-db.com/exploits/47683 https://github.com/k8gege/CVE-2019-0708 https://github.com/n1xbyte/CVE-2019-0708 https://github.com/victor0013/CVE-2019-0708 https://github.com/cbwang505/CVE-2019-0708-EXP-Windows https://github.com/Leoid/CVE-2019-0708 https://github.com/p0p0p0/CVE-2019-0708-exploit https://github.com/worawit • CWE-416: Use After Free •
CVE-2018-4845
https://notcve.org/view.php?id=CVE-2018-4845
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). Remote attackers with either local or remote credentialed access to the "Remote View" feature might be able to elevate their privileges, compromising confidentiality, integrity, and availability of the system. No special skills or user interaction are required to perform this attack. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue. • https://cert-portal.siemens.com/productcert/pdf/ssa-755010.pdf • CWE-269: Improper Privilege Management CWE-284: Improper Access Control •
CVE-2018-4846
https://notcve.org/view.php?id=CVE-2018-4846
A vulnerability has been identified in RAPIDLab 1200 systems / RAPIDPoint 400 systems / RAPIDPoint 500 systems (All versions_without_ use of Siemens Healthineers Informatics products), RAPIDLab 1200 Series (All versions < V3.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions >= V3.0 _with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (V2.4.X_with_ Siemens Healthineers Informatics products), RAPIDPoint 500 systems (All versions =< V2.3 _with_ Siemens Healthineers Informatics products), RAPIDPoint 400 systems (All versions _with_ Siemens Healthineers Informatics products). A factory account with hardcoded password might allow attackers access to the device over port 5900/tcp. Successful exploitation requires no user interaction or privileges and impacts the confidentiality, integrity, and availability of the affected device. At the time of advisory publication, no public exploitation of this security vulnerability is known. Siemens Healthineers confirms the security vulnerability and provides mitigations to resolve the security issue. • https://cert-portal.siemens.com/productcert/pdf/ssa-755010.pdf • CWE-798: Use of Hard-coded Credentials •