10 results (0.002 seconds)

CVSS: 8.6EPSS: 0%CPEs: 34EXPL: 0

A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (All versions < V7.1.2), RUGGEDCOM RM1224 LTE(4G) NAM (All versions < V7.1.2), SCALANCE M804PB (All versions < V7.1.2), SCALANCE M812-1 ADSL-Router (Annex A) (All versions < V7.1.2), SCALANCE M812-1 ADSL-Router (Annex B) (All versions < V7.1.2), SCALANCE M816-1 ADSL-Router (Annex A) (All versions < V7.1.2), SCALANCE M816-1 ADSL-Router (Annex B) (All versions < V7.1.2), SCALANCE M826-2 SHDSL-Router (All versions < V7.1.2), SCALANCE M874-2 (All versions < V7.1.2), SCALANCE M874-3 (All versions < V7.1.2), SCALANCE M876-3 (EVDO) (All versions < V7.1.2), SCALANCE M876-3 (ROK) (All versions < V7.1.2), SCALANCE M876-4 (All versions < V7.1.2), SCALANCE M876-4 (EU) (All versions < V7.1.2), SCALANCE M876-4 (NAM) (All versions < V7.1.2), SCALANCE MUM853-1 (EU) (All versions < V7.1.2), SCALANCE MUM856-1 (EU) (All versions < V7.1.2), SCALANCE MUM856-1 (RoW) (All versions < V7.1.2), SCALANCE S615 (All versions < V7.1.2), SCALANCE S615 EEC (All versions < V7.1.2), SCALANCE WAM763-1 (All versions >= V1.1.0 < V2.0), SCALANCE WAM766-1 (EU) (All versions >= V1.1.0 < V2.0), SCALANCE WAM766-1 (US) (All versions >= V1.1.0 < V2.0), SCALANCE WAM766-1 EEC (EU) (All versions >= V1.1.0 < V2.0), SCALANCE WAM766-1 EEC (US) (All versions >= V1.1.0 < V2.0), SCALANCE WUM763-1 (All versions >= V1.1.0 < V2.0), SCALANCE WUM763-1 (All versions >= V1.1.0 < V2.0), SCALANCE WUM766-1 (EU) (All versions >= V1.1.0 < V2.0), SCALANCE WUM766-1 (US) (All versions >= V1.1.0 < V2.0). Affected devices with TCP Event service enabled do not properly handle malformed packets. This could allow an unauthenticated remote attacker to cause a denial of service condition and reboot the device thus possibly affecting other network resources. Se ha identificado una vulnerabilidad en RUGGEDCOM RM1224 LTE(4G) EU (Todas las versiones anteriores a V7.1.2), RUGGEDCOM RM1224 LTE(4G) NAM (Todas las versiones anteriores a V7.1.2), SCALANCE M804PB (Todas las versiones anteriores a V7.1. 2), SCALANCE M812-1 ADSL-Router (Anexo A) (Todas las versiones anteriores a V7.1.2), SCALANCE M812-1 ADSL-Router (Anexo B) (Todas las versiones anteriores a V7.1.2), SCALANCE M816-1 ADSL-Router (Anexo A) (Todas las versiones anteriores a V7.1. 2), SCALANCE M816-1 ADSL-Router (Anexo B) (Todas las versiones anteriores a V7.1.2), SCALANCE M826-2 SHDSL-Router (Todas las versiones anteriores a V7.1.2), SCALANCE M874-2 (Todas las versiones anteriores a V7.1.2), SCALANCE M874-3 (Todas las versiones anteriores a V7. 1.2), SCALANCE M876-3 (EVDO) (Todas las versiones anteriores a V7.1.2), SCALANCE M876-3 (ROK) (Todas las versiones anteriores a V7.1.2), SCALANCE M876-4 (EU) (Todas las versiones anteriores a V7.1.2), SCALANCE M876-4 (NAM) (Todas las versiones anteriores a V7. 1.2), SCALANCE MUM853-1 (EU) (Todas las versiones anteriores a V7.1.2), SCALANCE MUM856-1 (EU) (Todas las versiones anteriores a V7.1.2), SCALANCE MUM856-1 (RoW) (Todas las versiones anteriores a V7.1.2), SCALANCE S615 (Todas las versiones anteriores a V7. 1.2), SCALANCE WAM763-1 (Todas las versiones posteriores a V1.1.0 incluyéndola), SCALANCE WAM766-1 (Todas las versiones posteriores a V1.1.0 incluyéndola), SCALANCE WAM766-1 (Todas las versiones posteriores a V1.1.0 incluyéndola), SCALANCE WAM766-1 6GHz (Todas las versiones posteriores a V1.1. 0 incluyéndola), SCALANCE WAM766-1 EEC (Todas las versiones posteriores a V1.1.0 incluyéndola), SCALANCE WAM766-1 EEC (Todas las versiones posteriores a V1.1.0 incluyéndola), SCALANCE WAM766-1 EEC 6GHz (Todas las versiones posteriores a V1.1.0 incluyéndola), SCALANCE WUM763-1 (Todas las versiones posteriores a V1. 1.0 incluyéndola), SCALANCE WUM763-1 (Todas las versiones posteriores a V1.1.0 incluyéndola), SCALANCE WUM766-1 (Todas las versiones posteriores a V1.1.0 incluyéndola), SCALANCE WUM766-1 (Todas las versiones posteriores a V1.1.0 incluyéndola), SCALANCE WUM766-1 6GHz (Todas las versiones posteriores a V1.1.0 incluyéndola). Los dispositivos afectados con el servicio de eventos TCP activado no manejan apropiadamente los paquetes malformados. Esto podría permitir a un atacante remoto no autenticado causar una denegación de servicio y reiniciar el dispositivo, lo que podría afectar a otros recursos de red • https://cert-portal.siemens.com/productcert/pdf/ssa-697140.pdf • CWE-20: Improper Input Validation •

CVSS: 4.3EPSS: 0%CPEs: 60EXPL: 1

libcurl keeps previously used connections in a connection pool for subsequenttransfers to reuse, if one of them matches the setup.Due to errors in the logic, the config matching function did not take 'issuercert' into account and it compared the involved paths *case insensitively*,which could lead to libcurl reusing wrong connections.File paths are, or can be, case sensitive on many systems but not all, and caneven vary depending on used file systems.The comparison also didn't include the 'issuer cert' which a transfer can setto qualify how to verify the server certificate. libcurl mantiene las conexiones usadas previamente en un pool de conexiones para reusarlas en posteriores transferencias, si una de ellas coincide con la configuración. Debido a errores en la lógica, la función de coincidencia de la configuración no tenía en cuenta "issuercert" y comparaba las rutas implicadas *sin tener en cuenta el caso*, que podía conllevar a que libcurl reusara conexiones erróneas. Las rutas de los archivos son, o pueden ser, casos confidenciales en muchos sistemas, pero no en todos, y pueden incluso variar dependiendo de los sistemas de archivos usados. La comparación tampoco incluía el "issuercert" que una transferencia puede ajustar para calificar cómo verificar el certificado del servidor A flaw was found in libcurl in the way libcurl handles previously used connections without accounting for 'issuer cert' and comparing the involved paths case-insensitively. This flaw allows libcurl to use the wrong connection. • https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-484086.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-732250.pdf https://hackerone.com/reports/1223565 https://lists.apache.org/thread.html/r61db8e7dcb56dc000a5387a88f7a473bacec5ee01b9ff3f55308aacc%40%3Cdev.kafka.apache.org%3E https://lists.apache.org/thread.html/r61db8e7dcb56dc000a5387a88f7a473bacec5ee01b9ff3f55308aacc%40%3Cusers.kafka.apache.org%3E https://lists.apache.org/thread.html/rbf4ce74b0d1fa9810dec50ba3ace0c • CWE-20: Improper Input Validation CWE-295: Improper Certificate Validation CWE-706: Use of Incorrectly-Resolved Name or Reference •

CVSS: 7.5EPSS: 0%CPEs: 157EXPL: 0

Affected devices contain a vulnerability that allows an unauthenticated attacker to trigger a denial-of-service condition. The vulnerability can be triggered if a large amount of DCP reset packets are sent to the device. Los dispositivos afectados contienen una vulnerabilidad que permite a un atacante no autentificado desencadenar una condición de denegación de servicio. La vulnerabilidad puede activarse si se envía una gran cantidad de paquetes de restablecimiento de DCP al dispositivo • https://cert-portal.siemens.com/productcert/pdf/ssa-599968.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-194-03 https://cert-portal.siemens.com/productcert/html/ssa-599968.html • CWE-770: Allocation of Resources Without Limits or Throttling •

CVSS: 8.8EPSS: 0%CPEs: 35EXPL: 0

A vulnerability has been identified in RUGGEDCOM RM1224 (All versions >= V4.3 and < V6.4), SCALANCE M-800 (All versions >= V4.3 and < V6.4), SCALANCE S615 (All versions >= V4.3 and < V6.4), SCALANCE SC-600 Family (All versions >= V2.0 and < V2.1.3), SCALANCE XB-200 (All versions < V4.1), SCALANCE XC-200 (All versions < V4.1), SCALANCE XF-200BA (All versions < V4.1), SCALANCE XM400 (All versions < V6.2), SCALANCE XP-200 (All versions < V4.1), SCALANCE XR-300WG (All versions < V4.1), SCALANCE XR500 (All versions < V6.2). Affected devices contain a stack-based buffer overflow vulnerability in the handling of STP BPDU frames that could allow a remote attacker to trigger a denial-of-service condition or potentially remote code execution. Successful exploitation requires the passive listening feature of the device to be active. Se ha identificado una vulnerabilidad en RUGGEDCOM RM1224 (Todas las versiones posteriores e incluyendo a V4.3 y anteriores a V6.4), SCALANCE M-800 (Todas las versiones posteriores e incluyendo a V4.3 y anteriores a V6.4), SCALANCE S615 (Todas las versiones posteriores e incluyendo a V4.3 y anteriores a V6.4), SCALANCE SC-600 Family (Todas las versiones posteriores e incluyendo a V2.0 y anteriores a V2.1.3), SCALANCE XB-200 (Todas las versiones anteriores a V4.1), SCALANCE XC-200 (Todas las versiones anteriores a V4.1), SCALANCE XF-200BA (Todas las versiones anteriores a V4.1), SCALANCE XM400 (Todas las versiones anteriores a V6.2), SCALANCE XP-200 (Todas las versiones anteriores a V4.1), SCALANCE XR-300WG (Todas las versiones anteriores a V4.1), SCALANCE XR500 (Todas las versiones anteriores a V6.2). Unos dispositivos afectados contienen una vulnerabilidad de desbordamiento de búfer en la región stack de la memoria en el manejo de frames STP BPDU que podría permitir a un atacante remoto desencadenar una condición de denegación de servicio o una ejecución de código potencialmente remoto. • https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-068-03 • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 7.8EPSS: 0%CPEs: 109EXPL: 0

Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device. Las versiones de la pila Profinet-IO (PNIO) anteriores a la V06.00 no limitan adecuadamente la asignación de recursos internos cuando se envían múltiples solicitudes legítimas de paquetes de diagnóstico a la interfaz DCE-RPC. Esto podría conducir a una condición de denegación de servicio debido a la falta de memoria para los dispositivos que incluyen una versión vulnerable de la pila. • https://cert-portal.siemens.com/productcert/html/ssa-780073.html https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf • CWE-400: Uncontrolled Resource Consumption •