CVE-2021-33737
https://notcve.org/view.php?id=CVE-2021-33737
A vulnerability has been identified in SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 ERPC (All versions), SIMATIC CP 343-1 Lean (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3). Sending a specially crafted packet to port 102/tcp of an affected device could cause a denial of service condition. • https://cert-portal.siemens.com/productcert/pdf/ssa-549234.pdf • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •
CVE-2020-25242
https://notcve.org/view.php?id=CVE-2020-25242
A vulnerability has been identified in SIMATIC NET CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Lean (incl. SIPLUS variants) (All versions), SIMATIC NET CP 343-1 Standard (incl. SIPLUS variants) (All versions). Specially crafted packets sent to TCP port 102 could cause a Denial-of-Service condition on the affected devices. • https://cert-portal.siemens.com/productcert/pdf/ssa-676775.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-131-07 • CWE-400: Uncontrolled Resource Consumption •
CVE-2019-13946
https://notcve.org/view.php?id=CVE-2019-13946
Profinet-IO (PNIO) stack versions prior V06.00 do not properly limit internal resource allocation when multiple legitimate diagnostic package requests are sent to the DCE-RPC interface. This could lead to a denial of service condition due to lack of memory for devices that include a vulnerable version of the stack. The security vulnerability could be exploited by an attacker with network access to an affected device. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise the availability of the device. Las versiones de la pila Profinet-IO (PNIO) anteriores a la V06.00 no limitan adecuadamente la asignación de recursos internos cuando se envían múltiples solicitudes legítimas de paquetes de diagnóstico a la interfaz DCE-RPC. Esto podría conducir a una condición de denegación de servicio debido a la falta de memoria para los dispositivos que incluyen una versión vulnerable de la pila. • https://cert-portal.siemens.com/productcert/html/ssa-780073.html https://cert-portal.siemens.com/productcert/pdf/ssa-780073.pdf • CWE-400: Uncontrolled Resource Consumption •
CVE-2018-4843
https://notcve.org/view.php?id=CVE-2018-4843
A vulnerability has been identified in SIMATIC S7-400 CPU 414-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 414F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416-3 PN/DP V7 (All versions < V7.0.3), SIMATIC S7-400 CPU 416F-3 PN/DP V7 (All versions < V7.0.3), SIMATIC CP 343-1 (incl. SIPLUS variants) (All versions), SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIMATIC ET 200pro IM154-8 PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200pro IM154-8F PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200pro IM154-8FX PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200S IM151-8 PN/DP CPU (All versions < V3.2.16), SIMATIC ET 200S IM151-8F PN/DP CPU (All versions < V3.2.16), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions < V1.7.0), SIMATIC S7-1500 Software Controller (All versions < V1.7.0), SIMATIC S7-300 CPU 314C-2 PN/DP (All versions < V3.3.16), SIMATIC S7-300 CPU 315-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 315F-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 315T-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317F-2 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317T-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 317TF-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 319-3 PN/DP (All versions < V3.2.16), SIMATIC S7-300 CPU 319F-3 PN/DP (All versions < V3.2.16), SIMATIC S7-400 CPU 412-2 PN V7 (All versions < V7.0.3), SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.9), SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) (All versions < V6.0.7), SIMATIC S7-410 CPU family (incl. • https://cert-portal.siemens.com/productcert/pdf/ssa-592007.pdf • CWE-20: Improper Input Validation •
CVE-2017-2681
https://notcve.org/view.php?id=CVE-2017-2681
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. Los paquetes PROFINET DCP especialmente diseñados que se envían en un segmento Ethernet local (capa 2) a un producto afectado podrían causar una condición de denegación de servicio de ese producto. • http://www.securityfocus.com/bid/98369 http://www.securitytracker.com/id/1038463 https://cert-portal.siemens.com/productcert/html/ssa-293562.html https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf • CWE-400: Uncontrolled Resource Consumption •