6 results (0.008 seconds)

CVSS: 7.5EPSS: 0%CPEs: 152EXPL: 0

Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a denial of service condition. A restart is needed to restore normal operations. Los dispositivos afectados manejan incorrectamente paquetes especialmente manipulados enviados al puerto 102/tcp. Esto podría permitir que un atacante cree una condición de denegación de servicio. Es necesario reiniciar para restaurar las operaciones normales. • https://cert-portal.siemens.com/productcert/html/ssa-280603.html https://cert-portal.siemens.com/productcert/html/ssa-592380.html https://cert-portal.siemens.com/productcert/pdf/ssa-280603.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-592380.pdf • CWE-416: Use After Free •

CVSS: 7.5EPSS: 0%CPEs: 158EXPL: 0

The OPC UA implementations (ANSI C and C++) in affected products contain an integer overflow vulnerability that could cause the application to run into an infinite loop during certificate validation. This could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. Las implementaciones de OPC UA (ANSI C y C++) en los productos afectados contienen una vulnerabilidad de desbordamiento de enteros que podría provocar que la aplicación se ejecute en un bucle infinito durante la validación del certificado. Esto podría permitir que un atacante remoto no autenticado cree una condición de denegación de servicio enviando un certificado especialmente manipulado. • https://cert-portal.siemens.com/productcert/html/ssa-118850.html https://cert-portal.siemens.com/productcert/html/ssa-711309.html https://cert-portal.siemens.com/productcert/pdf/ssa-118850.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-711309.pdf • CWE-190: Integer Overflow or Wraparound •

CVSS: 7.5EPSS: 0%CPEs: 147EXPL: 0

Affected devices improperly handle large amounts of specially crafted UDP packets. This could allow an unauthenticated remote attacker to trigger a denial of service condition. Se ha identificado una vulnerabilidad en Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200, Kits de desarrollo/evaluación para PROFINET IO: EK-ERTEC 200P, SIMATIC CFU PA, SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. variantes SIPLUS), SIMATIC ET200AL, SIMATIC ET200M (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN BA (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN HF (incl. variantes SIPLUS), SIMATIC ET200MP IM155-5 PN ST (incl. variantes SIPLUS) SIPLUS), SIMATIC ET200S (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN BA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HA (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HS (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN ST (incl. variantes SIPLUS). SIPLUS), SIMATIC ET200SP IM155-6 PN/2 HF (incl. variantes SIPLUS), SIMATIC ET200SP IM155-6 PN/3 HF (incl. variantes SIPLUS) variantes SIPLUS), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, paneles exteriores SIMATIC HMI Comfort de 7" y 15" (incl. variantes SIPLUS), paneles SIMATIC HMI Comfort de 4" a 22" (incl. variantes SIPLUS), paneles móviles SIMATIC HMI KTP, acoplador SIMATIC PN/PN (incl. variantes SIPLUS NET), driver SIMATIC PROFINET, familia de CPUs SIMATIC S7-1200 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-1500 (incl. variantes SIPLUS). CPUs ET200 y variantes SIPLUS), SIMATIC S7-1500 Software Controller, familia de CPUs SIMATIC S7-300 (incl. CPUs ET200 y variantes SIPLUS), familia de CPUs SIMATIC S7-400 H V6 (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V6 e inferiores (incl. variantes SIPLUS), familia de CPUs SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS), SIMATIC S7-400 PN/DP V7 (incl. variantes SIPLUS). • https://cert-portal.siemens.com/productcert/html/ssa-473245.html https://cert-portal.siemens.com/productcert/pdf/ssa-473245.pdf • CWE-400: Uncontrolled Resource Consumption •

CVSS: 8.7EPSS: 0%CPEs: 76EXPL: 0

Specially crafted packets sent to port 161/udp could cause a denial of service condition. The affected devices must be restarted manually. Se ha identificado una vulnerabilidad en Development/Evaluation Kits para PROFINET IO: DK Standard Ethernet Controller, Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200, Development/Evaluation Kits para PROFINET IO: EK-ERTEC 200P, SIMATIC Compact Field Unit, SIMATIC ET200AL, SIMATIC ET200M (incluidas las variantes SIPLUS), SIMATIC ET200MP IM155-5 PN BA (incluidas las variantes SIPLUS), SIMATIC ET200MP IM155-5 PN HF (incluidas las variantes SIPLUS), SIMATIC ET200MP IM155-5 PN ST (incluidas las variantes SIPLUS), SIMATIC ET200S (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN BA (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HA (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HF (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN HS (incluidas las variantes SIPLUS), SIMATIC ET200SP IM155-6 PN ST (incluidas las variantes SIPLUS), SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 4AO U/I 4xM12, SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12, SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12, SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12, SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12, SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12, SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12, SIMATIC ET200ecoPN: IO-Link Master, SIMATIC ET200pro, SIMATIC PN/PN Coupler (incluidas las variantes SIPLUS NET), familia SIMATIC S7-1200 CPU (incluidas las variantes SIPLUS), familia SIMATIC S7-1500 CPU (incluyendo las variantes relacionadas ET200 CPUs y SIPLUS), SIMATIC S7-1500 Software Controller, SIMATIC S7-200 SMART, familia SIMATIC S7-300 CPU (incluyendo las variantes relacionadas ET200 CPUs y SIPLUS), SIMATIC S7-400 H V6 CPU familia y posteriores (incluidas las variantes SIPLUS), SIMATIC S7-400 PN/DP V6 CPU familia y posteriores (incluidas las variantes SIPLUS), familia SIMATIC S7-400 PN/DP V7 CPU (incluidas las variantes SIPLUS), familia SIMATIC S7-410 V8 CPU (incluidas las variantes SIPLUS), SIMATIC TDC CP51M1, SIMATIC TDC CPU555, SIMATIC WinAC RTX (F) 2010, SIMOCODE pro V EIP (incluidas las variantes SIPLUS), SIMOCODE pro V PN (incluidas las variantes SIPLUS), SIMOTION C, SIMOTION D (incluidas las variantes SIPLUS), SIMOTION D4xx V4.4 para SINAMICS SM150i-2 w. PROFINET (incluidas las variantes SIPLUS), SIMOTION P V4.4 and V4.5, SIMOTION P V5, SINAMICS DCM w. PN, SINAMICS DCP w. • https://cert-portal.siemens.com/productcert/html/ssa-141614.html https://cert-portal.siemens.com/productcert/html/ssa-346262.html https://cert-portal.siemens.com/productcert/html/ssa-546832.html https://cert-portal.siemens.com/productcert/pdf/ssa-141614.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-346262.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-546832.pdf https://www.securityfocus.com/bid/101964 • CWE-400: Uncontrolled Resource Consumption •

CVSS: 7.1EPSS: 0%CPEs: 181EXPL: 0

Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected. This vulnerability affects only SIMATIC HMI Multi Panels and HMI Mobile Panels, and S7-300/S7-400 devices. Los paquetes PROFINET DCP especialmente diseñados que se envían en un segmento Ethernet local (capa 2) a un producto afectado podrían causar una condición de denegación de servicio de ese producto. • http://www.securityfocus.com/bid/98369 http://www.securitytracker.com/id/1038463 https://cert-portal.siemens.com/productcert/html/ssa-293562.html https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf • CWE-400: Uncontrolled Resource Consumption •