6 results (0.003 seconds)

CVSS: 9.4EPSS: 0%CPEs: 9EXPL: 0

A vulnerability has been identified in SIMATIC BATCH V9.1 (All versions), SIMATIC Information Server 2020 (All versions), SIMATIC Information Server 2022 (All versions), SIMATIC PCS 7 V9.1 (All versions), SIMATIC Process Historian 2020 (All versions), SIMATIC Process Historian 2022 (All versions), SIMATIC WinCC Runtime Professional V18 (All versions), SIMATIC WinCC Runtime Professional V19 (All versions), SIMATIC WinCC V7.4 (All versions), SIMATIC WinCC V7.5 (All versions < V7.5 SP2 Update 18), SIMATIC WinCC V8.0 (All versions < V8.0 Update 5). The affected products run their DB server with elevated privileges which could allow an authenticated attacker to execute arbitrary OS commands with administrative privileges. • https://cert-portal.siemens.com/productcert/html/ssa-629254.html • CWE-250: Execution with Unnecessary Privileges •

CVSS: 7.1EPSS: 0%CPEs: 14EXPL: 0

In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions. En WIBU CodeMeter Runtime versiones anteriores a 7.30a, la creación de un enlace simbólico CmDongles diseñado sobrescribirá el archivo enlazado sin comprobar los permisos • https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf https://www.wibu.com/us/support/security-advisories.html • CWE-59: Improper Link Resolution Before File Access ('Link Following') •

CVSS: 8.1EPSS: 0%CPEs: 7EXPL: 0

A vulnerability has been identified in SIMATIC Process Historian 2013 and earlier (All versions), SIMATIC Process Historian 2014 (All versions < SP3 Update 6), SIMATIC Process Historian 2019 (All versions), SIMATIC Process Historian 2020 (All versions). An interface in the software that is used for critical functionalities lacks authentication, which could allow a malicious user to maliciously insert, modify or delete data. Se ha identificado una vulnerabilidad en SIMATIC Process Historian 2013 y anteriores (Todas las versiones), SIMATIC Process Historian 2014 (Todas las versiones anteriores a SP3 Update 6), SIMATIC Process Historian 2019 (Todas las versiones), SIMATIC Process Historian 2020 (Todas las versiones). Una interfaz en el software que es usada para funcionalidades críticas carece de autenticación, lo que podría permitir a un usuario malicioso insertar, modificar o eliminar datos de forma maliciosa • https://cert-portal.siemens.com/productcert/pdf/ssa-766247.pdf • CWE-306: Missing Authentication for Critical Function •

CVSS: 7.5EPSS: 0%CPEs: 12EXPL: 0

In OPC Foundation Local Discovery Server (LDS) before 1.04.402.463, remote attackers can cause a denial of service (DoS) by sending carefully crafted messages that lead to Access of a Memory Location After the End of a Buffer. En OPC Foundation Local Discovery Server (LDS) versiones anteriores a 1.04.402.463, unos atacantes remotos pueden causar una denegación de servicio (DoS) mediante el envío de mensajes cuidadosamente diseñados que conllevan a el Acceso a una Ubicación de Memoria Después del Final de un Búfer. • https://cert-portal.siemens.com/productcert/pdf/ssa-321292.pdf https://files.opcfoundation.org/SecurityBulletins/OPC%20Foundation%20Security%20Bulletin%20CVE-2021-40142.pdf https://opcfoundation.org/security-bulletins • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 9.1EPSS: 9%CPEs: 18EXPL: 1

A buffer over-read vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server. Se presenta una vulnerabilidad de lectura excesiva del búfer en Wibu-Systems CodeMeter versiones anteriores a 7.21a. Un atacante remoto no autenticado puede explotar este problema para revelar el contenido de la memoria de la pila o bloquear el CodeMeter Runtime Server • https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-01.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02 https://www.tenable.com/security/research/tra-2021-24 • CWE-125: Out-of-bounds Read •