CVE-2022-46141
https://notcve.org/view.php?id=CVE-2022-46141
12 Dec 2023 — A vulnerability has been identified in SIMATIC STEP 7 (TIA Portal) (All versions < V19). An information disclosure vulnerability could allow a local attacker to gain access to the access level password of the SIMATIC S7-1200 and S7-1500 CPUs, when entered by a legitimate user in the hardware configuration of the affected application. Se ha identificado una vulnerabilidad en SIMATIC STEP 7 (TIA Portal) (todas las versiones < V19). Una vulnerabilidad de divulgación de información podría permitir a un ataca... • https://cert-portal.siemens.com/productcert/pdf/ssa-887801.pdf • CWE-312: Cleartext Storage of Sensitive Information CWE-316: Cleartext Storage of Sensitive Information in Memory •

CVE-2020-7581
https://notcve.org/view.php?id=CVE-2020-7581
14 Jul 2020 — A vulnerability has been identified in Opcenter Execution Discrete (All versions < V3.2), Opcenter Execution Foundation (All versions < V3.2), Opcenter Execution Process (All versions < V3.2), Opcenter Intelligence (All versions < V3.3), Opcenter Quality (All versions < V11.3), Opcenter RD&L (V8.0), SIMATIC Notifier Server for Windows (All versions), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16... • https://cert-portal.siemens.com/productcert/pdf/ssa-841348.pdf • CWE-428: Unquoted Search Path or Element •

CVE-2020-7580
https://notcve.org/view.php?id=CVE-2020-7580
10 Jun 2020 — A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 S... • https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf • CWE-428: Unquoted Search Path or Element •

CVE-2019-10929
https://notcve.org/view.php?id=CVE-2019-10929
13 Aug 2019 — A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 ... • https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf • CWE-327: Use of a Broken or Risky Cryptographic Algorithm •

CVE-2016-7959
https://notcve.org/view.php?id=CVE-2016-7959
13 Oct 2016 — Siemens SIMATIC STEP 7 (TIA Portal) before 14 improperly stores pre-shared key data in TIA project files, which makes it easier for local users to obtain sensitive information by leveraging access to a file and conducting a brute-force attack. Siemens SIMATIC STEP 7 (TIA Portal) en versiones anteriores a 14 almacena indebidamente los datos clave pre-compartidos en archivos de proyecto TIA, lo que hace más que sea más fácil para usuarios locales obtener información sensible aprovechando el acceso a un archiv... • http://www.securityfocus.com/bid/93551 • CWE-254: 7PK - Security Features •

CVE-2016-7960
https://notcve.org/view.php?id=CVE-2016-7960
13 Oct 2016 — Siemens SIMATIC STEP 7 (TIA Portal) before 14 uses an improper format for managing TIA project files during version updates, which makes it easier for local users to obtain sensitive configuration information via unspecified vectors. Siemens SIMATIC STEP 7 (TIA Portal) en versiones anteriores a 14 utiliza un formato indebido para la gestión de archivos de proyectos TIA durante las actualizaciones de versión, lo que hace que sea más fácil para usuarios locales obtener información de configuración sensible a ... • http://www.securityfocus.com/bid/93551 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVE-2015-1601
https://notcve.org/view.php?id=CVE-2015-1601
06 Apr 2015 — Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 allows man-in-the-middle attackers to obtain sensitive information or modify transmitted data via unspecified vectors. Siemens SIMATIC STEP 7 (TIA Portal) 12 y 13 anterior a 13 SP1 Upd1 permite a atacantes man-in-the-middle obtener información sensible o modificar los datos transmitidos a través de vectores no especificados. • http://www.securityfocus.com/bid/72691 • CWE-254: 7PK - Security Features •

CVE-2015-1602
https://notcve.org/view.php?id=CVE-2015-1602
06 Apr 2015 — Siemens SIMATIC STEP 7 (TIA Portal) 12 and 13 before 13 SP1 Upd1 improperly stores password data within project files, which makes it easier for local users to determine cleartext (1) protection-level passwords or (2) web-server passwords by leveraging the ability to read these files. Siemens SIMATIC STEP 7 (TIA Portal) 12 y 13 anterior a 13 SP1 Upd1 almacena incorrectamente los datos de contraseñas dentro de ficheros de proyectos, lo que facilita a usuarios locales determinar (1) contraseñas del nivel de p... • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-315836.pdf • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •

CVE-2015-1355 – Siemens SIMATIC STEP 7 (TIA Portal) V13 Privilege Escalation
https://notcve.org/view.php?id=CVE-2015-1355
16 Feb 2015 — Siemens SIMATIC STEP 7 (TIA Portal) before 13 SP1 uses a weak password-hash algorithm, which makes it easier for local users to determine cleartext passwords by reading a project file and conducting a brute-force attack. Siemens SIMATIC STEP 7 (TIA Portal) anterior a 13 SP1 utiliza un algoritmo de hashes de contraseñas débil, lo que facilita a usuarios locales determinar las contraseñas en texto claro mediante la lectura de un ficheros de proyectos y la realización de un ataque de fuerza bruta. The latest u... • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-234789.pdf • CWE-310: Cryptographic Issues •

CVE-2015-1356 – Siemens SIMATIC STEP 7 (TIA Portal) V13 Privilege Escalation
https://notcve.org/view.php?id=CVE-2015-1356
16 Feb 2015 — Siemens SIMATIC STEP 7 (TIA Portal) before 13 SP1 determines a user's privileges on the basis of project-file fields that lack integrity protection, which allows remote attackers to establish arbitrary authorization data via a modified file. Siemens SIMATIC STEP 7 (TIA Portal) anterior a 13 SP1 determina los privilegios de un usuario basándose en campos de ficheros de proyectos que no tienen la protección de integridad, lo que permite a atacantes remotos establecer una autorización arbitraria a través de un... • http://www.siemens.com/innovation/pool/de/forschungsfelder/siemens_security_advisory_ssa-234789.pdf • CWE-264: Permissions, Privileges, and Access Controls •