4 results (0.013 seconds)

CVSS: 5.4EPSS: 0%CPEs: 4EXPL: 0

A vulnerability has been identified in SIMATIC WinCC OA V3.15 (All versions < V3.15 P038), SIMATIC WinCC OA V3.16 (All versions < V3.16 P035), SIMATIC WinCC OA V3.17 (All versions < V3.17 P024), SIMATIC WinCC OA V3.18 (All versions < V3.18 P014). The affected component allows to inject custom arguments to the Ultralight Client backend application under certain circumstances. This could allow an authenticated remote attacker to inject arbitrary parameters when starting the client via the web interface (e.g., open attacker chosen panels with the attacker's credentials or start a Ctrl script). Se ha identificado una vulnerabilidad en: SIMATIC WinCC OA V3.15 (todas las versiones &lt; V3.15 P038), SIMATIC WinCC OA V3.16 (todas las versiones &lt; V3.16 P035), SIMATIC WinCC OA V3.17 (todas las versiones &lt; ; V3.17 P024), SIMATIC WinCC OA V3.18 (Todas las versiones &lt; V3.18 P014). El componente afectado permite inyectar argumentos personalizados a la aplicación backend de Ultralight Client en determinadas circunstancias. Esto podría permitir a un atacante remoto autenticado inyectar parámetros arbitrarios al iniciar el cliente a través de la interfaz web (por ejemplo, abrir paneles elegidos por el atacante con las credenciales del atacante o iniciar un script Ctrl). • https://cert-portal.siemens.com/productcert/pdf/ssa-547714.pdf • CWE-88: Improper Neutralization of Argument Delimiters in a Command ('Argument Injection') •

CVSS: 7.1EPSS: 0%CPEs: 14EXPL: 0

In WIBU CodeMeter Runtime before 7.30a, creating a crafted CmDongles symbolic link will overwrite the linked file without checking permissions. En WIBU CodeMeter Runtime versiones anteriores a 7.30a, la creación de un enlace simbólico CmDongles diseñado sobrescribirá el archivo enlazado sin comprobar los permisos • https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210910-01.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf https://www.wibu.com/us/support/security-advisories.html • CWE-59: Improper Link Resolution Before File Access ('Link Following') •

CVSS: 9.1EPSS: 11%CPEs: 18EXPL: 1

A buffer over-read vulnerability exists in Wibu-Systems CodeMeter versions < 7.21a. An unauthenticated remote attacker can exploit this issue to disclose heap memory contents or crash the CodeMeter Runtime Server. Se presenta una vulnerabilidad de lectura excesiva del búfer en Wibu-Systems CodeMeter versiones anteriores a 7.21a. Un atacante remoto no autenticado puede explotar este problema para revelar el contenido de la memoria de la pila o bloquear el CodeMeter Runtime Server • https://cdn.wibu.com/fileadmin/wibu_downloads/security_advisories/Advisory_WIBU-210423-01.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-675303.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-210-02 https://www.tenable.com/security/research/tra-2021-24 • CWE-125: Out-of-bounds Read •

CVSS: 7.8EPSS: 0%CPEs: 68EXPL: 0

A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions < V1.1.0), SIMATIC RF600R family (All versions < V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.5 < V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions < V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions < V15.1 Upd 4), SINEC NMS (All versions < V1.0 SP1), SINEMA Server (All versions < V14 SP2), SINUMERIK OPC UA Server (All versions < V2.1), TeleControl Server Basic (All versions < V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. • https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf • CWE-248: Uncaught Exception CWE-755: Improper Handling of Exceptional Conditions •