CVE-2020-7580
https://notcve.org/view.php?id=CVE-2020-7580
10 Jun 2020 — A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 S... • https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf • CWE-428: Unquoted Search Path or Element •

CVE-2019-10929
https://notcve.org/view.php?id=CVE-2019-10929
13 Aug 2019 — A vulnerability has been identified in SIMATIC CP 1626 (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V20.8), SIMATIC HMI Panel (incl. SIPLUS variants) (All versions), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.4.0), SIMATIC S7-1500 ... • https://cert-portal.siemens.com/productcert/pdf/ssa-232418.pdf • CWE-327: Use of a Broken or Risky Cryptographic Algorithm •

CVE-2019-6575
https://notcve.org/view.php?id=CVE-2019-6575
17 Apr 2019 — A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V2.7), SIMATIC HMI Comfort Outdoor Panels 7" & 15" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI Comfort Panels 4" - 22" (incl. SIPLUS variants) (All versions < V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions < V5.1.... • https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf • CWE-248: Uncaught Exception CWE-755: Improper Handling of Exceptional Conditions •

CVE-2018-3991
https://notcve.org/view.php?id=CVE-2018-3991
05 Feb 2019 — An exploitable heap overflow vulnerability exists in the WkbProgramLow function of WibuKey Network server management, version 6.40.2402.500. A specially crafted TCP packet can cause a heap overflow, potentially leading to remote code execution. An attacker can send a malformed TCP packet to trigger this vulnerability. Existe una vulnerabilidad de desbordamiento de memoria dinámica (heap) explotable en la función WkbProgramLow de WibuKey Network server management en su versión 6.40.2402.500. Un paquete TCP e... • http://www.securityfocus.com/bid/107005 • CWE-787: Out-of-bounds Write •

CVE-2018-13799
https://notcve.org/view.php?id=CVE-2018-13799
12 Sep 2018 — A vulnerability has been identified in SIMATIC WinCC OA V3.14 and prior (All versions < V3.14-P021). Improper access control to a data point of the affected product could allow an unauthenticated remote user to escalate its privileges in the context of SIMATIC WinCC OA V3.14. This vulnerability could be exploited by an attacker with network access to port 5678/TCP of the SIMATIC WinCC OA V3.14 server. Successful exploitation requires no user privileges and no user interaction. This vulnerability could allow... • http://www.securityfocus.com/bid/105332 • CWE-269: Improper Privilege Management •

CVE-2014-0160 – OpenSSL Information Disclosure Vulnerability
https://notcve.org/view.php?id=CVE-2014-0160
07 Apr 2014 — The (1) TLS and (2) DTLS implementations in OpenSSL 1.0.1 before 1.0.1g do not properly handle Heartbeat Extension packets, which allows remote attackers to obtain sensitive information from process memory via crafted packets that trigger a buffer over-read, as demonstrated by reading private keys, related to d1_both.c and t1_lib.c, aka the Heartbleed bug. Las implementaciones de (1) TLS y (2) DTLS en OpenSSL 1.0.1 en versiones anteriores a 1.0.1g no manejan adecuadamente paquetes Heartbeat Extension, lo qu... • https://packetstorm.news/files/id/180746 • CWE-125: Out-of-bounds Read CWE-201: Insertion of Sensitive Information Into Sent Data •

CVE-2014-1696
https://notcve.org/view.php?id=CVE-2014-1696
07 Feb 2014 — Siemens SIMATIC WinCC OA before 3.12 P002 January uses a weak hash algorithm for passwords, which makes it easier for remote attackers to obtain access via a brute-force attack. Siemens SIMATIC WinCC OA anterior a 3.12 P002 January usa un algoritmo hash débil para las contraseñas, lo que hace más fácil para atacantes remotos obtener acceso a través de un ataque de fuerza bruta. • http://ics-cert.us-cert.gov/advisories/ICSA-14-035-01 • CWE-310: Cryptographic Issues •

CVE-2014-1697
https://notcve.org/view.php?id=CVE-2014-1697
07 Feb 2014 — The integrated web server in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to execute arbitrary code via crafted packets to TCP port 4999. El servidor Web integrado en Siemens SIMATIC WinCC OA anterior a 3.12 P002 January permite a atacantes remotos ejecutar código arbitrario a través de paquetes manipulados hacia el puerto TCP 4999. • http://ics-cert.us-cert.gov/advisories/ICSA-14-035-01 •

CVE-2014-1698
https://notcve.org/view.php?id=CVE-2014-1698
07 Feb 2014 — Directory traversal vulnerability in Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to read arbitrary files via crafted packets to TCP port 4999. Vulnerabilidad de salto de directorio en Siemens SIMATIC WinCC OA anterior a 3.12 P002 January permite a atacantes remotos leer archivos arbitrarios a través de paquetes manipulados hacia el puerto TCP 4999. • http://ics-cert.us-cert.gov/advisories/ICSA-14-035-01 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVE-2014-1699
https://notcve.org/view.php?id=CVE-2014-1699
07 Feb 2014 — Siemens SIMATIC WinCC OA before 3.12 P002 January allows remote attackers to cause a denial of service (monitoring-service outage) via malformed HTTP requests to port 4999. Siemens SIMATIC WinCC OA anterior a 3.12 P002 January permite a atacantes remotos causar una denegación de servicio (interrupción del servicio de monitorización) a través de peticiones HTTP malformadas hacia el puerto TCP 4999. • http://ics-cert.us-cert.gov/advisories/ICSA-14-035-01 • CWE-399: Resource Management Errors •