4 results (0.017 seconds)

CVSS: 7.4EPSS: 0%CPEs: 6EXPL: 0

A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name record decompression functionality does not properly validate the pointer offset values. The parsing of malformed responses could result in a read access past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition. Se ha identificado una vulnerabilidad en Nucleus NET (Todas las versiones), Nucleus ReadyStart V3 (Todas las versiones anteriores a V2017.02.3), Nucleus ReadyStart V4 (Todas las versiones anteriores a V4.1.0), Nucleus Source Code (Versiones que incluyen los módulos DNS afectados), SIMOTICS CONNECT 400 (Todas las versiones anteriores a V0.5.0.0). • https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-788: Access of Memory Location After End of Buffer •

CVSS: 6.5EPSS: 0%CPEs: 6EXPL: 0

A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS response parsing functionality does not properly validate various length and counts of the records. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the memory past the allocated structure. Se ha identificado una vulnerabilidad en Nucleus NET (Todas las versiones), Nucleus ReadyStart V3 (Todas las versiones anteriores a la versión V2017.02.3), Nucleus ReadyStart V4 (Todas las versiones anteriores a la versión V4.1.0), Nucleus Source Code (Versiones que incluyen los módulos DNS afectados), SIMOTICS CONNECT 400 (Todas las versiones anteriores a la versión V0.5.0.0). • https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf • CWE-125: Out-of-bounds Read •

CVSS: 6.5EPSS: 0%CPEs: 6EXPL: 0

A vulnerability has been identified in APOGEE PXC Compact (BACnet) (All versions < V3.5.5), APOGEE PXC Compact (P2 Ethernet) (All versions < V2.8.20), APOGEE PXC Modular (BACnet) (All versions < V3.5.5), APOGEE PXC Modular (P2 Ethernet) (All versions < V2.8.20), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus ReadyStart V4 (All versions < V4.1.0), Nucleus Source Code (Versions including affected DNS modules), SIMOTICS CONNECT 400 (All versions < V0.5.0.0), TALON TC Compact (BACnet) (All versions < V3.5.5), TALON TC Modular (BACnet) (All versions < V3.5.5). The DNS domain name label parsing functionality does not properly validate the null-terminated name in DNS-responses. The parsing of malformed responses could result in a read past the end of an allocated structure. An attacker with a privileged position in the network could leverage this vulnerability to cause a denial-of-service condition or leak the read memory. Se ha identificado una vulnerabilidad en Nucleus NET (Todas las versiones), Nucleus ReadyStart V3 (Todas las versiones anteriores a V2017.02.3), Nucleus ReadyStart V4 (Todas las versiones anteriores a V4.1.0), Nucleus Source Code (Versiones que incluyen los módulos DNS afectados), SIMOTICS CONNECT 400 (Todas las versiones anteriores a V0.5.0.0). • https://cert-portal.siemens.com/productcert/pdf/ssa-180579.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf • CWE-125: Out-of-bounds Read CWE-170: Improper Null Termination •

CVSS: 7.1EPSS: 0%CPEs: 46EXPL: 0

A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions < V2303), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.3), Nucleus Source Code (All versions). By sending specially crafted DHCP packets to a device where the DHCP client is enabled, an attacker could change the IP address of the device to an invalid value. Se ha identificado una vulnerabilidad en APOGEE MEC/MBC/PXC (P2) (Todas las versiones anteriores a V2.8.2), APOGEE PXC Series (BACnet) (Todas las versiones anteriores a V3.5.3), APOGEE PXC Series (P2) (Todas las versiones posteriores o iguales a V2. 8.2 y anteriores a V2.8.19), Desigo PXC00-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC00-U (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC001-E. D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC100-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC12-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00. 327), Desigo PXC128-U (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC200-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC22-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00. 327), Desigo PXC22.1-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC36.1-E.D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC50-E. D (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXC64-U (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00.327), Desigo PXM20-E (Todas las versiones posteriores o iguales a V2.3x y anteriores a V6.00. 327), Nucleus NET (Todas las versiones), Nucleus RTOS (Todas las versiones), Nucleus ReadyStart para ARM, MIPS y PPC (Todas las versiones anteriores a V2017.02.2 con parche "Nucleus 2017.02. 02 Nucleus NET Patch"), Nucleus SafetyCert (Todas las versiones), Nucleus Source Code (Todas las versiones), SIMOTICS CONNECT 400 (Todas las versiones anteriores a V0.3.0.330), TALON TC Series (BACnet) (Todas las versiones anteriores a V3.5.3), VSTAR (Todas las versiones). • https://cert-portal.siemens.com/productcert/html/ssa-162506.html https://cert-portal.siemens.com/productcert/html/ssa-434032.html https://cert-portal.siemens.com/productcert/pdf/ssa-162506.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-434032.pdf https://us-cert.cisa.gov/ics/advisories/icsa-20-105-06 • CWE-20: Improper Input Validation •