8 results (0.008 seconds)

CVSS: 9.8EPSS: 0%CPEs: 6EXPL: 0

The Telnet service of the SIMATIC HMI Comfort Panels system component in affected products does not require authentication, which may allow a remote attacker to gain access to the device if the service is enabled. Telnet is disabled by default on the SINAMICS Medium Voltage Products (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions). El servicio Telnet del componente del sistema SIMATIC HMI Comfort Panels en los productos afectados no requiere autenticación, lo que puede permitir a un atacante remoto conseguir acceso al dispositivo si el servicio está habilitado. Telnet está desactivado por defecto en los productos SINAMICS Medium Voltage (SINAMICS SL150: Todas las versiones, SINAMICS SM150: Todas las versiones, SINAMICS SM150i: Todas las versiones) • https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04 • CWE-306: Missing Authentication for Critical Function •

CVSS: 9.8EPSS: 0%CPEs: 6EXPL: 0

SINAMICS medium voltage routable products are affected by a vulnerability in the Sm@rtServer component for remote access that could allow an unauthenticated attacker to cause a denial-of-service condition, and/or execution of limited configuration modifications and/or execution of limited control commands on the SINAMICS Medium Voltage Products, Remote Access (SINAMICS SL150: All versions, SINAMICS SM150: All versions, SINAMICS SM150i: All versions). Los productos enrutables de tensión media SINAMICS están afectados por una vulnerabilidad en el componente Sm@rtServer para el acceso remoto que podría permitir a un atacante no autenticado causar una condición de denegación de servicio, y/o una ejecución de modificaciones de configuración limitadas y/o la ejecución de comandos de control limitados en los productos de media tensión SINAMICS, acceso remoto (SINAMICS SL150: Todas las versiones, SINAMICS SM150: Todas las versiones, SINAMICS SM150i: Todas las versiones) • https://us-cert.cisa.gov/ics/advisories/icsa-21-131-04 • CWE-20: Improper Input Validation •

CVSS: 7.5EPSS: 0%CPEs: 155EXPL: 0

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). • https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 • CWE-401: Missing Release of Memory after Effective Lifetime •

CVSS: 7.5EPSS: 0%CPEs: 155EXPL: 0

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). • https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 • CWE-400: Uncontrolled Resource Consumption CWE-835: Loop with Unreachable Exit Condition ('Infinite Loop') •

CVSS: 7.5EPSS: 0%CPEs: 155EXPL: 0

A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). • https://cert-portal.siemens.com/productcert/pdf/ssa-286838.pdf https://cert-portal.siemens.com/productcert/pdf/ssa-538778.pdf https://us-cert.cisa.gov/ics/advisories/icsa-21-131-12 • CWE-770: Allocation of Resources Without Limits or Throttling •