3 results (0.004 seconds)

CVSS: 7.3EPSS: 0%CPEs: 17EXPL: 0

A vulnerability has been identified in SIMATIC S7-PLCSIM V16 (All versions), SIMATIC S7-PLCSIM V17 (All versions), SIMATIC STEP 7 Safety V16 (All versions), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 8), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 5), SIMATIC STEP 7 V16 (All versions), SIMATIC STEP 7 V17 (All versions < V17 Update 8), SIMATIC STEP 7 V18 (All versions < V18 Update 5), SIMATIC WinCC Unified V16 (All versions), SIMATIC WinCC Unified V17 (All versions < V17 Update 8), SIMATIC WinCC Unified V18 (All versions < V18 Update 5), SIMATIC WinCC V16 (All versions), SIMATIC WinCC V17 (All versions < V17 Update 8), SIMATIC WinCC V18 (All versions < V18 Update 5), SIMOCODE ES V16 (All versions), SIMOCODE ES V17 (All versions < V17 Update 8), SIMOCODE ES V18 (All versions), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 8), SIRIUS Safety ES V18 (All versions), SIRIUS Soft Starter ES V17 (All versions < V17 Update 8), SIRIUS Soft Starter ES V18 (All versions), TIA Portal Cloud V16 (All versions), TIA Portal Cloud V17 (All versions < V4.6.0.1), TIA Portal Cloud V18 (All versions < V4.6.1.0). Affected products do not properly sanitize user-controllable input when parsing user settings. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. • https://cert-portal.siemens.com/productcert/html/ssa-871035.html • CWE-502: Deserialization of Untrusted Data •

CVSS: 7.0EPSS: 0%CPEs: 6EXPL: 0

A vulnerability has been identified in SIMATIC STEP 7 Safety V16 (All versions < V16 Update 7), SIMATIC STEP 7 Safety V17 (All versions < V17 Update 7), SIMATIC STEP 7 Safety V18 (All versions < V18 Update 2), SIMATIC STEP 7 V16 (All versions < V16 Update 7), SIMATIC STEP 7 V17 (All versions < V17 Update 7), SIMATIC STEP 7 V18 (All versions < V18 Update 2), SIMATIC WinCC Unified V16 (All versions < V16 Update 7), SIMATIC WinCC Unified V17 (All versions < V17 Update 7), SIMATIC WinCC Unified V18 (All versions < V18 Update 2), SIMATIC WinCC V16 (All versions < V16.7), SIMATIC WinCC V17 (All versions < V17.7), SIMATIC WinCC V18 (All versions < V18 Update 2), SIMOCODE ES V16 (All versions < V16 Update 7), SIMOCODE ES V17 (All versions < V17 Update 7), SIMOCODE ES V18 (All versions < V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (All versions), SIMOTION SCOUT TIA V5.4 SP3 (All versions), SIMOTION SCOUT TIA V5.5 SP1 (All versions), SINAMICS Startdrive V16 (All versions), SINAMICS Startdrive V17 (All versions), SINAMICS Startdrive V18 (All versions), SIRIUS Safety ES V17 (All versions < V17 Update 7), SIRIUS Safety ES V18 (All versions < V18 Update 2), SIRIUS Soft Starter ES V17 (All versions < V17 Update 7), SIRIUS Soft Starter ES V18 (All versions < V18 Update 2), Soft Starter ES V16 (All versions < V16 Update 7), TIA Portal Cloud V3.0 (All versions < V18 Update 2). Affected applications do not properly restrict the .NET BinaryFormatter when deserializing hardware configuration profiles. This could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. This is the same issue that exists for .NET BinaryFormatter https://docs.microsoft.com/en-us/visualstudio/code-quality/ca2300. Se ha identificado una vulnerabilidad en SIMATIC STEP 7 Safety V16 (todas las versiones &lt; V16 Update 7), SIMATIC STEP 7 Safety V17 (todas las versiones &lt; V17 Update 7), SIMATIC STEP 7 Safety V18 (todas las versiones &lt; V18 Update 2), SIMATIC STEP 7 V16 (todas las versiones &lt; V16 Update 7), SIMATIC STEP 7 V17 (todas las versiones &lt; V17 Update 7), SIMATIC STEP 7 V18 (todas las versiones &lt; V18 Update 2), SIMATIC WinCC Unified V16 (todas las versiones &lt; V16 Update 7), SIMATIC WinCC Unified V17 (todas las versiones &lt; V17 Update 7), SIMATIC WinCC Unified V18 (todas las versiones &lt; V18 Update 2), SIMATIC WinCC V16 (todas las versiones &lt; V16.7), SIMATIC WinCC V17 (todas las versiones &lt; V17.7), SIMATIC WinCC V18 (todas las versiones &lt; V18 Update 2), SIMOCODE ES V16 (todas las versiones &lt; V16 Update 7), SIMOCODE ES V17 (todas las versiones &lt; V17 Update 7), SIMOCODE ES V18 (todas las versiones &lt; V18 Update 2), SIMOTION SCOUT TIA V5.4 SP1 (Todas las versiones), SIMOTION SCOUT TIA V5.4 SP3 (Todas las versiones), SIMOTION SCOUT TIA V5.5 SP1 (Todas las versiones), SINAMICS Startdrive V16 (Todas las versiones), SINAMICS Startdrive V17 (Todas las versiones), SINAMICS Startdrive V18 (todas las versiones), SIRIUS Safety ES V17 (todas las versiones &lt; V17 Update 7), SIRIUS Safety ES V18 (todas las versiones &lt; V18 Update 2), SIRIUS Soft Starter ES V17 (todas las versiones &lt; V17 Update 7), SIRIUS Soft Starter ES V18 (Todas las versiones &lt; V18 Actualización 2), Soft Starter ES V16 (Todas las versiones &lt; V16 Actualización 7), TIA Portal Cloud V3.0 (Todas las versiones &lt; V18 Actualización 2). Las aplicaciones afectadas no restringen adecuadamente .NET BinaryFormatter al deserializar perfiles de configuración de hardware. • https://cert-portal.siemens.com/productcert/html/ssa-779936.html • CWE-502: Deserialization of Untrusted Data •

CVSS: 7.2EPSS: 0%CPEs: 44EXPL: 0

A vulnerability has been identified in SIMATIC Automation Tool (All versions < V4 SP2), SIMATIC NET PC Software V14 (All versions < V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC NET PC Software V16 (All versions < V16 Upd3), SIMATIC PCS neo (All versions < V3.0 SP1), SIMATIC ProSave (All versions < V17), SIMATIC S7-1500 Software Controller (All versions < V21.8), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (All versions < V15.1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (All versions < V16 Update 2), SIMATIC STEP 7 V5 (All versions < V5.6 SP2 HF3), SIMATIC WinCC OA V3.16 (All versions < V3.16 P018), SIMATIC WinCC OA V3.17 (All versions < V3.17 P003), SIMATIC WinCC Runtime Advanced (All versions < V16 Update 2), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (All versions < V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (All versions < V16 Update 2), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (All versions < V7.5 SP1 Update 3), SINAMICS STARTER (All Versions < V5.4 HF2), SINAMICS Startdrive (All Versions < V16 Update 3), SINEC NMS (All versions < V1.0 SP2), SINEMA Server (All versions < V14 SP3), SINUMERIK ONE virtual (All Versions < V6.14), SINUMERIK Operate (All Versions < V6.14). A common component used by the affected applications regularly calls a helper binary with SYSTEM privileges while the call path is not quoted. This could allow a local attacker to execute arbitrary code with SYTEM privileges. Se ha identificado una vulnerabilidad en SIMATIC Automation Tool (Todas las versiones anteriores a la versión V4 SP2), SIMATIC NET PC Software V14 (Todas las versiones anteriores a la versión V14 SP1 Update 14), SIMATIC NET PC Software V15 (Todas las versiones), SIMATIC NET PC Software V16 (Todas las versiones anteriores a la versión V16 Upd3), SIMATIC PCS neo (Todas las versiones anteriores a la versión V3.0 SP1), SIMATIC ProSave (Todas las versiones anteriores a la versión V17), SIMATIC S7-1500 Software Controller (Todas las versiones anteriores a la versión V21. 8), SIMATIC STEP 7 (Todas las versiones anteriores a la versión V5.6 SP2 HF3), SIMATIC STEP 7 (TIA Portal) V13 (Todas las versiones anteriores a la versión V13 SP2 Update 4), SIMATIC STEP 7 (TIA Portal) V14 (Todas las versiones anteriores a la versión V14 SP1 Update 10), SIMATIC STEP 7 (TIA Portal) V15 (Todas las versiones anteriores a la versión V15. 1 Update 5), SIMATIC STEP 7 (TIA Portal) V16 (Todas las versiones anteriores a la versión V16 Update 2), SIMATIC WinCC OA V3.16 (Todas las versiones anteriores a la versión V3.16 P018), SIMATIC WinCC OA V3. 17 (Todas las versiones anteriores a la versión V3.17 P003), SIMATIC WinCC Runtime Advanced (Todas las versiones anteriores a la versión V16 Update 2), SIMATIC WinCC Runtime Professional V13 (Todas las versiones anteriores a la versión V13 SP2 Update 4), SIMATIC WinCC Runtime Professional V14 (Todas las versiones anteriores a la versión V14 SP1 Update 10), SIMATIC WinCC Runtime Professional V15 (Todas las versiones anteriores a la versión V15.1 Update 5), SIMATIC WinCC Runtime Professional V16 (Todas las versiones anteriores a la versión V16 Update 2), SIMATIC WinCC V7. 4 (Todas las versiones anteriores a la versión V7.4 SP1 Update 14), SIMATIC WinCC V7.5 (Todas las versiones anteriores a la versión V7.5 SP1 Update 3), SINAMICS STARTER (Todas las versiones anteriores a la versión V5.4 HF2), SINAMICS Startdrive (Todas las versiones anteriores a la versión V16 Update 3), SINEC NMS (Todas las versiones anteriores a la versión V1. 0 SP2), SINEMA Server (Todas las versiones anteriores a la versión V14 SP3), SINUMERIK ONE virtual (Todas las versiones anteriores a la versión V6.14), SINUMERIK Operate (Todas las versiones anteriores a la versión V6.14). Un componente dentro de la aplicación afectada llama regularmente a un binario de ayuda con privilegios de SISTEMA mientras la ruta de llamada no está citada • https://cert-portal.siemens.com/productcert/pdf/ssa-312271.pdf https://us-cert.cisa.gov/ics/advisories/icsa-20-161-04 • CWE-428: Unquoted Search Path or Element •