CVE-2022-43768
https://notcve.org/view.php?id=CVE-2022-43768
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-7 LTE EU (All versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8 IRC (All versions), SIMATIC CP 1542SP-1 (All versions), SIMATIC CP 1542SP-1 IRC (All versions), SIMATIC CP 1543SP-1 (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions), SIPLUS NET CP 1242-7 V2 (All versions), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (All versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product. • https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf https://cert-portal.siemens.com/productcert/html/ssa-139628.html https://cert-portal.siemens.com/productcert/html/ssa-566905.html • CWE-770: Allocation of Resources Without Limits or Throttling •
CVE-2022-43767
https://notcve.org/view.php?id=CVE-2022-43767
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-7 LTE EU (All versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8 IRC (All versions), SIMATIC CP 1542SP-1 (All versions), SIMATIC CP 1542SP-1 IRC (All versions), SIMATIC CP 1543SP-1 (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions), SIPLUS NET CP 1242-7 V2 (All versions), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (All versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product. • https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf https://cert-portal.siemens.com/productcert/html/ssa-139628.html https://cert-portal.siemens.com/productcert/html/ssa-566905.html • CWE-833: Deadlock •
CVE-2022-43716
https://notcve.org/view.php?id=CVE-2022-43716
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (All versions), SIMATIC CP 1243-1 (All versions), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions), SIMATIC CP 1243-7 LTE EU (All versions), SIMATIC CP 1243-7 LTE US (All versions), SIMATIC CP 1243-8 IRC (All versions), SIMATIC CP 1542SP-1 (All versions), SIMATIC CP 1542SP-1 IRC (All versions), SIMATIC CP 1543SP-1 (All versions), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 (All versions < V3.3), SIMATIC CP 443-1 Advanced (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (All versions), SIPLUS ET 200SP CP 1543SP-1 ISEC (All versions), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (All versions), SIPLUS NET CP 1242-7 V2 (All versions), SIPLUS NET CP 443-1 (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (All versions), SIPLUS S7-1200 CP 1243-1 RAIL (All versions), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product. • https://cert-portal.siemens.com/productcert/pdf/ssa-566905.pdf https://cert-portal.siemens.com/productcert/html/ssa-139628.html https://cert-portal.siemens.com/productcert/html/ssa-566905.html • CWE-416: Use After Free •
CVE-2021-37205
https://notcve.org/view.php?id=CVE-2021-37205
A vulnerability has been identified in SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions >= V4.5.0 < V4.5.2), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions >= V2.9.2 < V2.9.4), SIMATIC S7-1500 Software Controller (All versions >= V21.9 < V21.9.4), SIMATIC S7-PLCSIM Advanced (All versions >= V4.0 < V4.0 SP1), SIPLUS TIM 1531 IRC (All versions < V2.3.6), TIM 1531 IRC (All versions < V2.3.6). An unauthenticated attacker could cause a denial-of-service condition in a PLC when sending specially prepared packets over port 102/tcp. A restart of the affected device is needed to restore normal operations. • https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf • CWE-401: Missing Release of Memory after Effective Lifetime •
CVE-2021-37204
https://notcve.org/view.php?id=CVE-2021-37204
A vulnerability has been identified in SIMATIC Drive Controller family (All versions < V2.9.2), SIMATIC Drive Controller family (All versions >= V2.9.2 < V2.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC (incl. SIPLUS variants) (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions < V21.9), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions >= V21.9 < V21.9.4), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 Ready4Linux (All versions), SIMATIC S7-1200 CPU family (incl. SIPLUS variants) (All versions < V4.5.0), SIMATIC S7-1200 CPU family (incl. • https://cert-portal.siemens.com/productcert/pdf/ssa-838121.pdf • CWE-672: Operation on a Resource after Expiration or Release •