4 results (0.003 seconds)

CVSS: 9.0EPSS: 0%CPEs: 1EXPL: 1

A vulnerability was found in Tenda AC8 16.03.34.09 and classified as critical. Affected by this issue is the function route_static_check of the file /goform/SetStaticRouteCfg. The manipulation of the argument list leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. • https://tasty-foxtrot-3a8.notion.site/Tenda-AC8v4-route_static_check-stack-overflow-1460448e6195803087a5d39755d2bb6b?pvs=74 https://vuldb.com/?ctiid.286142 https://vuldb.com/?id.286142 https://vuldb.com/?submit.449893 https://www.tenda.com.cn • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-121: Stack-based Buffer Overflow •

CVSS: 9.0EPSS: 0%CPEs: 1EXPL: 1

A vulnerability classified as critical has been found in Tenda AC8 16.03.34.09. Affected is the function fromAdvSetMacMtuWan of the file /goform/AdvSetMacMtuWan. The manipulation of the argument wanMTU/wanSpeed/cloneType/mac/serviceName/serverName leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/fromAdvSetMacMtuWan.md https://vuldb.com/?ctiid.261792 https://vuldb.com/?id.261792 https://vuldb.com/?submit.316495 • CWE-121: Stack-based Buffer Overflow •

CVSS: 9.0EPSS: 0%CPEs: 1EXPL: 1

A vulnerability was found in Tenda AC8 16.03.34.09. It has been rated as critical. This issue affects the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be initiated remotely. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/formSetRebootTimer.md https://vuldb.com/?ctiid.261791 https://vuldb.com/?id.261791 https://vuldb.com/?submit.316494 • CWE-121: Stack-based Buffer Overflow •

CVSS: 9.0EPSS: 0%CPEs: 1EXPL: 1

A vulnerability was found in Tenda AC8 16.03.34.09. It has been declared as critical. This vulnerability affects the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. The attack can be initiated remotely. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AC8/R7WebsSecurityHandler.md https://vuldb.com/?ctiid.261790 https://vuldb.com/?id.261790 https://vuldb.com/?submit.316493 • CWE-121: Stack-based Buffer Overflow •