CVE-2023-38823
https://notcve.org/view.php?id=CVE-2023-38823
Buffer Overflow vulnerability in Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 and v.1.0 allows a remote attacker to execute arbitrary code via the formSetCfm function in bin/httpd. Vulnerabilidad de desbordamiento del búfer en Tenda Ac19 v.1.0, AC18, AC9 v.1.0, AC6 v.2.0 y v.1.0 permite a un atacante remoto ejecutar código arbitrario a través de la función formSetCfm en bin/httpd. • https://github.com/nhtri2003gmail/CVE_report/blob/master/CVE-2023-38823.md https://github.com/johnathanhuutri/CVE_report/blob/master/CVE-2023-38823/README.md • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •
CVE-2023-38933
https://notcve.org/view.php?id=CVE-2023-38933
Tenda AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6 and AC9 V3.0 V15.03.06.42_multi, and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the deviceId parameter in the formSetClientState function. • https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetClientState/README.md • CWE-787: Out-of-bounds Write •
CVE-2023-38931
https://notcve.org/view.php?id=CVE-2023-38931
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, F1203 V2.0.1.6, AC5 V1.0 V15.03.06.28, AC10 v4.0 V16.03.10.13 and FH1203 V2.0.1.6 were discovered to contain a stack overflow via the list parameter in the setaccount function. • https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/cloudv2_setaccount/README.md • CWE-787: Out-of-bounds Write •
CVE-2023-38937
https://notcve.org/view.php?id=CVE-2023-38937
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC8 v4 V16.03.34.06, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, AC9 V3.0 V15.03.06.42_multi and AC10 v4.0 V16.03.10.13 were discovered to contain a stack overflow via the list parameter in the formSetVirtualSer function. • https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetVirtualSer/README.md • CWE-787: Out-of-bounds Write •
CVE-2023-38936
https://notcve.org/view.php?id=CVE-2023-38936
Tenda AC10 V1.0 V15.03.06.23, AC1206 V15.03.06.23, AC6 V2.0 V15.03.06.23, AC7 V1.0 V15.03.06.44, AC5 V1.0 V15.03.06.28, FH1203 V2.0.1.6, AC9 V3.0 V15.03.06.42_multi and FH1205 V2.0.0.7(775) were discovered to contain a stack overflow via the speed_dir parameter in the formSetSpeedWan function. • https://github.com/FirmRec/IoT-Vulns/blob/main/tenda/formSetSpeedWan/README.md • CWE-787: Out-of-bounds Write •