Page 102 of 1479 results (0.010 seconds)

CVSS: 4.4EPSS: 0%CPEs: 43EXPL: 0

In gnss service, there is a possible out of bounds write due to improper input validation. This could lead to local information disclosure with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS08017370; Issue ID: ALPS08017370. En el servicio gnss, existe una posible escritura fuera de límites debido a una validación de entrada incorrecta. • https://corp.mediatek.com/product-security-bulletin/September-2023 • CWE-787: Out-of-bounds Write •

CVSS: 6.7EPSS: 0%CPEs: 40EXPL: 0

In gnss service, there is a possible out of bounds write due to improper input validation. This could lead to local esclation of privileges with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS08017365; Issue ID: ALPS08017365. En el servicio gnss, existe una posible escritura fuera de límites debido a una validación de entrada incorrecta. • https://corp.mediatek.com/product-security-bulletin/September-2023 • CWE-787: Out-of-bounds Write •

CVSS: 6.7EPSS: 0%CPEs: 22EXPL: 0

In connectivity system driver, there is a possible out of bounds write due to improper input validation. This could lead to local escalation of privilege with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS07929848; Issue ID: ALPS07929848. En connectivity system driver, existe una posible escritura fuera de límites debido a una validación de entrada incorrecta. • https://corp.mediatek.com/product-security-bulletin/September-2023 • CWE-20: Improper Input Validation CWE-787: Out-of-bounds Write •

CVSS: 4.4EPSS: 0%CPEs: 45EXPL: 0

In bluetooth driver, there is a possible out of bounds read due to improper input validation. This could lead to local information leak with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS07867212; Issue ID: ALPS07867212. En el controlador Bluetooth, existe una posible lectura fuera de los límites debido a una validación de entrada incorrecta. • https://corp.mediatek.com/product-security-bulletin/September-2023 • CWE-125: Out-of-bounds Read •

CVSS: 4.4EPSS: 0%CPEs: 35EXPL: 0

In bluetooth driver, there is a possible read and write access to registers due to improper access control of register interface. This could lead to local leak of sensitive information with System execution privileges needed. User interaction is not needed for exploitation. Patch ID: ALPS07849753; Issue ID: ALPS07849753. En bluetooth driver, existe un posible acceso de lectura y escritura a los registros debido a un control de acceso inadecuado de la interfaz de registro. • https://corp.mediatek.com/product-security-bulletin/September-2023 •