CVSS: 7.5EPSS: 0%CPEs: 20EXPL: 0

ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - Programmable Logic Controllers, multiple versions. Researchers have found some controllers are susceptible to a denial-of-service attack due to a flood of network packets. En Controladores lógicos programables de ABB, Phoenix Contact, Schneider Electric, Siemens, WAGO - , versiones múltiples. Los investigadores han encontrado que algunos controladores son susceptibles a un ataque de Denegación de Servicio (DoS) debido a una inundación de paquetes de red. • http://www.securityfocus.com/bid/108413 https://ics-cert.us-cert.gov/advisories/ICSA-19-106-03 • CWE-400: Uncontrolled Resource Consumption CWE-770: Allocation of Resources Without Limits or Throttling •

CVSS: 7.3EPSS: 0%CPEs: 7EXPL: 0

A successful exploit of these vulnerabilities requires the local user to load a crafted DLL file in the system directory on servers running Schneider Electric OFS v3.5 with version v7.40 of SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 with version v7.30 of Vijeo Citect/CitectSCADA, and OFS v3.5 with version v7.20 of Vijeo Citect/CitectSCADA.. If the application attempts to open that file, the application could crash or allow the attacker to execute arbitrary code. Schneider Electric recommends vulnerable users upgrade the OFS to V3.5 and install the latest service pack (SP 6 or newer) for their associated version. Una explotación exitosa de estas vulnerabilidades requiere que el usuario local suba un archivo DLL manipulado en el directorio de sistemas en los servidores que ejecutan Schneider Electric OFS v3.5 con la versión v7.40 de SCADA Expert Vijeo Citect/CitectSCADA, OFS v3.5 con la versión v7.30 de Vijeo Citect/CitectSCADA y OFS v3.5 con la versiónv7.20 de Vijeo Citect/CitectSCADA. Si la aplicación intenta abrir ese archivo, podría cerrarse inesperadamente o permitir al atacante ejecutar código arbitrario. • https://ics-cert.us-cert.gov/advisories/ICSA-15-141-01 • CWE-427: Uncontrolled Search Path Element •

CVSS: 5.4EPSS: 0%CPEs: 22EXPL: 0

Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser. Cross-Site Scripting (XSS) reflejado (no persistente) permite que un atacante manipule una URL específica, que contiene JavaScript que se ejecutará en el navegador del cliente PLC de Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H o BMXP342030H. • https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 5.5EPSS: 0%CPEs: 22EXPL: 0

Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page. La inclusión de archivos remotos permite que un atacante manipule una URL específica que referencia al servidor web PLC de Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H o BMXP342030H, de Schneider Electric, el cual, una vez lanzado, resultará en la redirección del navegador a un archivo remoto mediante un script de Java cargado con la página web. • https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02 • CWE-20: Improper Input Validation CWE-98: Improper Control of Filename for Include/Require Statement in PHP Program ('PHP Remote File Inclusion') •

CVSS: 6.2EPSS: 0%CPEs: 1EXPL: 0

A Cryptographic Issue (CWE-310) vulnerability exists in IIoT Monitor 3.1.38 which could allow information disclosure. Existe una vulnerabilidad de problema criptográfico (CWE-310) en IIoT Monitor 3.1.38 que podría permitir la divulgación de información. This vulnerability allows the decryption of the administrator password on vulnerable installations of Schneider Electric IIoT Monitor. Authentication is not required to exploit this vulnerability. The specific flaw exists within encryption of the administrator password in the AESEncryption class. A hard-coded cryptographic key is used which can allow the reversal of the encryption process. • https://ics-cert.us-cert.gov/advisories/ICSA-19-008-02 https://www.schneider-electric.com/en/download/document/SEVD-2018-354-03 • CWE-310: Cryptographic Issues •