Page 11 of 53 results (0.005 seconds)

CVSS: 10.0EPSS: 2%CPEs: 30EXPL: 1

InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. A remote attacker could send a carefully crafted packet to exploit a stack-based buffer overflow vulnerability during tag, alarm, or event related actions such as read and write, with potential for code to be executed. If InduSoft Web Studio remote communication security was not enabled, or a password was left blank, a remote user could send a carefully crafted packet to invoke an arbitrary process, with potential for code to be executed. The code would be executed under the privileges of the InduSoft Web Studio or InTouch Edge HMI runtime and could lead to a compromise of the InduSoft Web Studio or InTouch Edge HMI server machine. InduSoft Web Studio en versiones anteriores a la 8.1 SP2 e InTouch Edge HMI (anteriormente llamado InTouch Machine Edition) en versiones anteriores a la 2017 SP2. • https://ics-cert.us-cert.gov/advisories/ICSA-18-305-01 https://www.tenable.com/security/research/tra-2018-34 • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •

CVSS: 10.0EPSS: 0%CPEs: 30EXPL: 1

InduSoft Web Studio versions prior to 8.1 SP2, and InTouch Edge HMI (formerly InTouch Machine Edition) versions prior to 2017 SP2. This vulnerability could allow an unauthenticated user to remotely execute code with the same privileges as that of the InduSoft Web Studio or InTouch Edge HMI (formerly InTouch Machine Edition) runtime. InduSoft Web Studio en versiones anteriores a la 8.1 SP2 e InTouch Edge HMI (anteriormente llamado InTouch Machine Edition) en versiones anteriores a la 2017 SP2. Esta vulnerabilidad podría permitir que un usuario no autenticado ejecute código remotamente con los mismos privilegios que los del tiempo de ejecución de InduSoft Web Studio o InTouch Edge HMI (anteriormente InTouch Machine Edition). • https://ics-cert.us-cert.gov/advisories/ICSA-18-305-01 https://www.tenable.com/security/research/tra-2018-34 • CWE-258: Empty Password in Configuration File •

CVSS: 10.0EPSS: 3%CPEs: 7EXPL: 1

Commvault Edge Communication Service (cvd) prior to version 11 SP7 or version 11 SP6 with hotfix 590 is prone to a stack-based buffer overflow vulnerability that could lead to arbitrary code execution with administrative privileges. Commvault Edge Communication Service (cvd) en su versión 11 SP7 o la versión 11 SP6 con hotfix 590 es vulnerable a un desbordamiento de búfer basado en pila, lo que puede conducir a una ejecución de código arbitrario con privilegios de administrador. • https://www.exploit-db.com/exploits/41823 http://kb.commvault.com/article/SEC0013 http://redr2e.com/commvault-edge-cve-2017-3195 http://www.securityfocus.com/bid/96941 https://www.kb.cert.org/vuls/id/214283 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-121: Stack-based Buffer Overflow •