Page 118 of 5095 results (0.076 seconds)

CVSS: 9.8EPSS: 0%CPEs: -EXPL: 0

An issue was discovered in SEMCMS v.4.8, allows remote attackers to execute arbitrary code, escalate privileges, and obtain sensitive information via the upload.php file. • https://github.com/ss122-0ss/semcmsv4.8/blob/main/readme.md • CWE-434: Unrestricted Upload of File with Dangerous Type •

CVSS: 7.8EPSS: 0%CPEs: 4EXPL: 0

A configuration setting issue in seccenter.exe as used in Bitdefender Total Security, Bitdefender Internet Security, Bitdefender Antivirus Plus, Bitdefender Antivirus Free allows an attacker to change the product's expected behavior and potentially load a third-party library upon execution. This issue affects Total Security: 27.0.25.114; Internet Security: 27.0.25.114; Antivirus Plus: 27.0.25.114; Antivirus Free: 27.0.25.114. Un problema de configuración en seccenter.exe tal como se usa en Bitdefender Total Security, Bitdefender Internet Security, Bitdefender Antivirus Plus, Bitdefender Antivirus Free permite a un atacante cambiar el comportamiento esperado del producto y potencialmente cargar una librería de terceros durante la ejecución. Este problema afecta a Total Security: 27.0.25.114; Seguridad de Internet: 27.0.25.114; Antivirus Plus: 27.0.25.114; Antivirus gratuito: 27.0.25.114. • https://bitdefender.com/support/security-advisories/local-privilege-escalation-in-bitdefender-total-security-va-11168 • CWE-15: External Control of System or Configuration Setting •

CVSS: 6.6EPSS: 0%CPEs: -EXPL: 0

In gnss, there is a possible escalation of privilege due to a missing bounds check. This could lead to local escalation of privilege with System execution privileges needed. ... Esto podría conducir a una escalada local de privilegios con permisos de ejecución de System necesarios. • https://corp.mediatek.com/product-security-bulletin/April-2024 • CWE-787: Out-of-bounds Write •

CVSS: 8.4EPSS: 0%CPEs: -EXPL: 0

This could lead to local escalation of privilege with System execution privileges needed. ... Esto podría conducir a una escalada local de privilegios con permisos de ejecución de System necesarios. • https://corp.mediatek.com/product-security-bulletin/April-2024 • CWE-787: Out-of-bounds Write •

CVSS: 6.6EPSS: 0%CPEs: 1EXPL: 0

In battery, there is a possible escalation of privilege due to an integer overflow. This could lead to local escalation of privilege with System execution privileges needed. ... Esto podría conducir a una escalada local de privilegios con permisos de ejecución de System necesarios. • https://corp.mediatek.com/product-security-bulletin/April-2024 • CWE-190: Integer Overflow or Wraparound •