CVE-2024-21753
https://notcve.org/view.php?id=CVE-2024-21753
A improper limitation of a pathname to a restricted directory ('path traversal') in Fortinet FortiClientEMS versions 7.2.0 through 7.2.4, 7.0.0 through 7.0.13, 6.4.0 through 6.4.9, 6.2.0 through 6.2.9, 6.0.0 through 6.0.8, 1.2.1 through 1.2.5 allows attacker to perform a denial of service, read or write a limited number of files via specially crafted HTTP requests Una limitación incorrecta de una ruta de acceso a un directorio restringido ("ruta de acceso") en las versiones 7.2.0 a 7.2.4, 7.0.0 a 7.0.13, 6.4.0 a 6.4.9, 6.2.0 a 6.2.9, 6.0.0 a 6.0.8, 1.2.1 a 1.2.5 de Fortinet FortiClientEMS permite a un atacante realizar una denegación de servicio, leer o escribir una cantidad limitada de archivos a través de solicitudes HTTP especialmente manipuladas. • https://fortiguard.fortinet.com/psirt/FG-IR-23-362 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •
CVE-2024-8645 – Access of Uninitialized Pointer in Wireshark
https://notcve.org/view.php?id=CVE-2024-8645
SPRT dissector crash in Wireshark 4.2.0 to 4.0.5 and 4.0.0 to 4.0.15 allows denial of service via packet injection or crafted capture file • https://gitlab.com/wireshark/wireshark/-/issues/19559 https://www.wireshark.org/security/wnpa-sec-2024-10.html • CWE-824: Access of Uninitialized Pointer •
CVE-2024-44087
https://notcve.org/view.php?id=CVE-2024-44087
This could allow an unauthenticated remote attacker to cause an integer overflow and crash of the application. This denial of service condition could prevent legitimate users from using subsequent products that rely on the affected application for license verification. • https://cert-portal.siemens.com/productcert/html/ssa-103653.html • CWE-190: Integer Overflow or Wraparound •
CVE-2024-43647
https://notcve.org/view.php?id=CVE-2024-43647
This could allow an unauthenticated remote attacker to cause a denial of service condition. To restore normal operations, the network cable of the device needs to be unplugged and re-plugged. • https://cert-portal.siemens.com/productcert/html/ssa-969738.html • CWE-400: Uncontrolled Resource Consumption •
CVE-2024-37993
https://notcve.org/view.php?id=CVE-2024-37993
The affected applications do not authenticated the creation of Ajax2App instances. This could allow an unauthenticated attacker to cause a denial of service condition. • https://cert-portal.siemens.com/productcert/html/ssa-765405.html • CWE-284: Improper Access Control •