CVE-2019-13542
https://notcve.org/view.php?id=CVE-2019-13542
3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition. 3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, todas las versiones desde 3.5.11.0 hasta 3.5.15.0, permite a un atacante enviar peticiones diseñadas desde un cliente OPC UA confiable que causa una desreferencia del puntero NULL, lo que puede desencadenar una condición de denegación de servicio. • https://www.us-cert.gov/ics/advisories/icsa-19-255-04 • CWE-476: NULL Pointer Dereference •
CVE-2019-9009
https://notcve.org/view.php?id=CVE-2019-9009
An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash. Se descubrió un problema en 3S-Smart CODESYS versiones anteriores a 3.5.15.0. Unos paquetes de red diseñados causan que el Control Runtime se bloquee. • https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12941&token=50fabe3870c7bdc41701eb1799dddeec103de40c&download= https://www.us-cert.gov/ics/advisories/icsa-19-255-05 • CWE-755: Improper Handling of Exceptional Conditions •
CVE-2019-13548
https://notcve.org/view.php?id=CVE-2019-13548
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution. El servidor web de CODESYS V3, todas las versiones anteriores a 3.5.14.10, permite a un atacante enviar peticiones http o https especialmente diseñadas que podrían causar un desbordamiento de la pila y crear una condición de denegación de servicio o permitir la ejecución de código remota. • https://www.us-cert.gov/ics/advisories/icsa-19-255-01 • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •
CVE-2019-13532
https://notcve.org/view.php?id=CVE-2019-13532
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which may allow access to files outside the restricted working directory of the controller. El servidor web de CODESYS V3, todas las versiones anteriores a 3.5.14.10, permite a un atacante enviar peticiones http o https especialmente diseñadas que pueden conceder el acceso a archivos fuera del directorio de trabajo restringido del controlador. • https://www.us-cert.gov/ics/advisories/icsa-19-255-01 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •
CVE-2019-9012
https://notcve.org/view.php?id=CVE-2019-9012
An issue was discovered in 3S-Smart CODESYS V3 products. A crafted communication request may cause uncontrolled memory allocations in the affected CODESYS products and may result in a denial-of-service condition. All variants of the following CODESYS V3 products in all versions prior to v3.5.14.20 that contain the CmpGateway component are affected, regardless of the CPU type or operating system: CODESYS Control for BeagleBone, CODESYS Control for emPC-A/iMX6, CODESYS Control for IOT2000, CODESYS Control for Linux, CODESYS Control for PFC100, CODESYS Control for PFC200, CODESYS Control for Raspberry Pi, CODESYS Control V3 Runtime System Toolkit, CODESYS Gateway V3, CODESYS V3 Development System. Se detectó un problema en los productos 3S-Smart CODESYS V3. Una petición de comunicación diseñada puede causar asignaciones de memoria no controladas en los productos CODESYS afectados y puede resultar en una condición de denegación de servicio. • https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12938&token=b9eb30f53246dc57b2e7cb302356a05547148fa2&download= https://www.us-cert.gov/ics/advisories/icsa-19-213-03 • CWE-770: Allocation of Resources Without Limits or Throttling •