Page 12 of 64 results (0.009 seconds)

CVSS: 6.7EPSS: 0%CPEs: 115EXPL: 0

Improper conditions check in BIOS firmware for some Intel(R) Processors may allow a privileged user to potentially enable escalation of privilege via local access. Una comprobación de condiciones inapropiadas en el firmware del BIOS para algunos Intel® Processors puede habilitar a un usuario privilegiado para permitir potencialmente una escalada de privilegios por medio de un acceso local • https://security.netapp.com/advisory/ntap-20201113-0001 https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00358 • CWE-754: Improper Check for Unusual or Exceptional Conditions •

CVSS: 7.8EPSS: 0%CPEs: 271EXPL: 0

Improper input validation in BIOS firmware for some Intel(R) Processors may allow an authenticated user to potentially enable escalation of privilege via local access. Una comprobación inapropiada de la entrada en el firmware del BIOS para algunos Intel® Processors puede habilitar a un usuario autenticado para permitir potencialmente una escalada de privilegios por medio de un acceso local • https://cert-portal.siemens.com/productcert/pdf/ssa-678983.pdf https://security.netapp.com/advisory/ntap-20201113-0001 https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00358 • CWE-20: Improper Input Validation •

CVSS: 5.5EPSS: 0%CPEs: 502EXPL: 0

Improper removal of sensitive information before storage or transfer in some Intel(R) Processors may allow an authenticated user to potentially enable information disclosure via local access. Una eliminación inapropiada de información confidencial antes del almacenamiento o transferencia en algunos Intel® Processors, puede habilitar a un usuario autenticado para permitir potencialmente una divulgación de información por medio de un acceso local A flaw was found in the Intel Advanced Vector Extensions (AVX) implementation, where a local authenticated attacker with the ability to execute AVX instructions can gather the AVX register state from previous AVX executions. This vulnerability allows information disclosure of the AVX register state. • https://lists.debian.org/debian-lts-announce/2021/02/msg00007.html https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/MAAGIK5CXKBPGY3R4UR5VO56M7MKLZ43 https://security.netapp.com/advisory/ntap-20201113-0006 https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00381 https://access.redhat.com/security/cve/CVE-2020-8696 https://bugzilla.redhat.com/show_bug.cgi?id=1890355 https://access.redhat.com/articles/5569051 • CWE-212: Improper Removal of Sensitive Information Before Storage or Transfer •

CVSS: 5.6EPSS: 0%CPEs: 1321EXPL: 0

Load value injection in some Intel(R) Processors utilizing speculative execution may allow an authenticated user to potentially enable information disclosure via a side channel with local access. The list of affected products is provided in intel-sa-00334: https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00334.html Una inyección de valor de carga en algunos Procesadores Intel® que utilizan una ejecución especulativa puede permitir a un usuario autenticado habilitar potencialmente una divulgación de información por medio de un canal lateral con acceso local. La lista de productos afectados es proporcionada en intel-sa-00334: https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00334.html • https://security.netapp.com/advisory/ntap-20200320-0002 https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00334.html •

CVSS: 5.3EPSS: 0%CPEs: 892EXPL: 0

Improper conditions check in multiple Intel® Processors may allow an authenticated user to potentially enable partial escalation of privilege, denial of service and/or information disclosure via local access. La verificación de condiciones inadecuadas en múltiples procesadores Intel® puede permitir a un usuario autenticado habilitar potencialmente la escalada parcial de privilegios, la denegación de servicio y / o la divulgación de información a través del acceso local. • https://security.netapp.com/advisory/ntap-20191217-0002 https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00317.html https://www.synology.com/security/advisory/Synology_SA_19_42 • CWE-754: Improper Check for Unusual or Exceptional Conditions •