CVE-2018-5391 – The Linux kernel, versions 3.9+, IP implementation is vulnerable to denial of service conditions with low rates of specially modified packets
https://notcve.org/view.php?id=CVE-2018-5391
The Linux kernel, versions 3.9+, is vulnerable to a denial of service attack with low rates of specially modified packets targeting IP fragment re-assembly. An attacker may cause a denial of service condition by sending specially crafted IP fragments. Various vulnerabilities in IP fragmentation have been discovered and fixed over the years. The current vulnerability (CVE-2018-5391) became exploitable in the Linux kernel with the increase of the IP fragment reassembly queue size. El kernel de Linux en versiones a partir de la 3.9 es vulnerable a un ataque de denegación de servicio (DoS) con tasas bajas de paquetes especialmente modificados que apuntan hacia el reensamblado de fragmentos de IP. • http://www.arubanetworks.com/assets/alert/ARUBA-PSA-2018-004.txt http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20200115-01-linux-en http://www.openwall.com/lists/oss-security/2019/06/28/2 http://www.openwall.com/lists/oss-security/2019/07/06/3 http://www.openwall.com/lists/oss-security/2019/07/06/4 http://www.securityfocus.com/bid/105108 http://www.securitytracker.com/id/1041476 http://www.securitytracker.com/id/1041637 https://access.redhat.co • CWE-20: Improper Input Validation CWE-400: Uncontrolled Resource Consumption •
CVE-2018-3639 – AMD / ARM / Intel - Speculative Execution Variant 4 Speculative Store Bypass
https://notcve.org/view.php?id=CVE-2018-3639
Systems with microprocessors utilizing speculative execution and speculative execution of memory reads before the addresses of all prior memory writes are known may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis, aka Speculative Store Bypass (SSB), Variant 4. Los sistemas con microprocesadores que emplean la ejecución especulativa y que realizan la ejecución especulativa de lecturas de memoria antes de que se conozcan las direcciones de todas las anteriores escrituras de memoria podrían permitir la divulgación no autorizada de información a un atacante con acceso de usuario local mediante un análisis de canal lateral. Esto también se conoce como Speculative Store Bypass (SSB), Variant 4. An industry-wide issue was found in the way many modern microprocessor designs have implemented speculative execution of Load & Store instructions (a commonly used performance optimization). It relies on the presence of a precisely-defined instruction sequence in the privileged code as well as the fact that memory read from address to which a recent memory write has occurred may see an older value and subsequently cause an update into the microprocessor's data cache even for speculatively executed instructions that never actually commit (retire). • https://www.exploit-db.com/exploits/44695 https://github.com/mmxsrup/CVE-2018-3639 https://github.com/Shuiliusheng/CVE-2018-3639-specter-v4- https://github.com/malindarathnayake/Intel-CVE-2018-3639-Mitigation_RegistryUpdate http://lists.opensuse.org/opensuse-security-announce/2019-05/msg00058.html http://lists.opensuse.org/opensuse-security-announce/2019-05/msg00059.html http://lists.opensuse.org/opensuse-security-announce/2020-09/msg00007.html http://support.lenovo.com/us/en/solutions/LEN-2213 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor CWE-203: Observable Discrepancy •
CVE-2016-7165
https://notcve.org/view.php?id=CVE-2016-7165
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent). Se ha identificado una vulnerabilidad en Primary Setup Tool (PST) (todas las versiones anteriores a V4.2 HF1), SIMATIC IT Production Suite (todas las versiones anteriores a V7.0 SP1 HFX 2), SIMATIC NET PC-Software (Todas las versiones anteriores a V14), SIMATIC PCS 7 versión V7.1 (Todas las versiones), SIMATIC PCS 7 versión V8.0 (Todas las versiones), SIMATIC PCS 7 versión V8.1 (Todas las versiones),SIMATIC PCS 7 versión V8.2 (Todas las versiones anteriores a V8.2 SP1), SIMATIC STEP 7 (TIA Portal) versión V13 (Todas las versiones anteriores a V13 SP2), SIMATIC STEP 7 versiones V5.X (Todas las versiones anteriores a V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (Todas las versiones anteriores a V14), SIMATIC WinCC (TIA Portal) Professional versión V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC (TIA Portal) Professional versión V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC Runtime Professional versión V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC Runtime Professional versión V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC versión V7.0 SP2 y anteriores (Todas las versiones anteriores a V7.0 SP2 Upd 12), SIMATIC WinCC versión V7.0 SP3 (Todas las versiones anteriores a V7.0 SP3 Upd 8), SIMATIC WinCC versión V7.2 (Todas las versiones anteriores a V7.2 Upd 14), SIMATIC WinCC versión V7.3 (Todas las versiones anteriores a V7.3 Upd 11), SIMATIC WinCC versión V7.4 (Todas las versiones anteriores a V7.4 SP1), SIMIT versión V9.0 (Todas las versiones anteriores a V9.0 SP1), SINEMA Remote Connect Client (Todas las versiones anteriores a V1.0 SP3), SINEMA Server (Todas las versiones anteriores a V13 SP2), SOFTNET Security Client versión V5.0 (Todas las versiones), Security Configuration Tool (SCT) (Todas las versiones anteriores a V4.3 HF1), TeleControl Server Basic (Todas las versiones anteriores a V3.0 SP2), WinAC RTX 2010 SP2 (Todas las versiones), WinAC RTX F 2010 SP2 (Todas las versiones). Las rutas (path) de servicio sin comillas podrían permitir que los usuarios locales del sistema operativo Microsoft Windows aumenten sus privilegios si los productos afectados no están instalados en su ruta (path) de acceso predeterminada ("C:\Program Files\*" o el equivalente localizado). • http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html http://www.securityfocus.com/bid/94158 https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02 • CWE-254: 7PK - Security Features CWE-284: Improper Access Control •
CVE-2016-6204
https://notcve.org/view.php?id=CVE-2016-6204
Cross-site scripting (XSS) vulnerability in the integrated web server in Siemens SINEMA Remote Connect Server before 1.2 allows remote attackers to inject arbitrary web script or HTML via a crafted URL. Vulnerabilidad de XSS en el servidor web integrado en Siemens SINEMA Remote Connect Server en versiones anteriores a 1.2 permite a atacantes remotos inyectar secuencias de comandos web o HTML arbitrarios a través de una URL manipulada. • http://www.securityfocus.com/bid/92114 http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-119132.pdf https://ics-cert.us-cert.gov/advisories/ICSA-16-208-03 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •