Page 12 of 909 results (0.005 seconds)

CVSS: 9.0EPSS: 0%CPEs: 1EXPL: 0

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W9/formQosManageDouble_user.md https://vuldb.com/?ctiid.262132 https://vuldb.com/?id.262132 https://vuldb.com/?submit.319823 • CWE-121: Stack-based Buffer Overflow •

CVSS: 9.0EPSS: 0%CPEs: 1EXPL: 0

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been classified as critical. This affects the function formQosManageDouble_user. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. It is possible to initiate the attack remotely. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/W9/formQosManageDouble_auto.md https://vuldb.com/?ctiid.262131 https://vuldb.com/?id.262131 https://vuldb.com/?submit.319822 • CWE-121: Stack-based Buffer Overflow •

CVSS: 9.0EPSS: 0%CPEs: 1EXPL: 1

A vulnerability was found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this issue is the function formSetRebootTimer of the file /goform/SetRebootTimer. The manipulation of the argument rebootTime leads to stack-based buffer overflow. The attack may be launched remotely. The exploit has been disclosed to the public and may be used. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AX/AX1806/formSetRebootTimer.md https://vuldb.com/?ctiid.262130 https://vuldb.com/?id.262130 https://vuldb.com/?submit.319235 • CWE-121: Stack-based Buffer Overflow •

CVSS: 9.0EPSS: 0%CPEs: 1EXPL: 1

A vulnerability has been found in Tenda AX1806 1.0.0.1 and classified as critical. Affected by this vulnerability is the function formSetDeviceName of the file /goform/SetOnlineDevName. The manipulation of the argument devName leads to stack-based buffer overflow. The attack can be launched remotely. The exploit has been disclosed to the public and may be used. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AX/AX1806/formSetDeviceName_devName.md https://vuldb.com/?ctiid.262129 https://vuldb.com/?id.262129 https://vuldb.com/?submit.319232 • CWE-121: Stack-based Buffer Overflow •

CVSS: 9.0EPSS: 0%CPEs: 1EXPL: 1

A vulnerability, which was classified as critical, was found in Tenda AX1806 1.0.0.1. Affected is the function R7WebsSecurityHandler of the file /goform/execCommand. The manipulation of the argument password leads to stack-based buffer overflow. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. • https://github.com/abcdefg-png/IoT-vulnerable/blob/main/Tenda/AX/AX1806/R7WebsSecurityHandler.md https://vuldb.com/?ctiid.262128 https://vuldb.com/?id.262128 https://vuldb.com/?submit.319231 • CWE-121: Stack-based Buffer Overflow •