Page 13 of 99 results (0.005 seconds)

CVSS: 4.3EPSS: 0%CPEs: 28EXPL: 0

A vulnerability in Cisco Nexus 9000 Series Fabric Switches in Application Centric Infrastructure (ACI) mode could allow an authenticated, remote attacker to access sensitive information. The vulnerability occurs because the affected software does not properly validate user-supplied input. An attacker could exploit this vulnerability by issuing certain commands with filtered query results on the device. This action may cause returned messages to display confidential system information. A successful exploit could allow the attacker to read sensitive information on the device. • https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190501-aci-filter-query • CWE-20: Improper Input Validation CWE-399: Resource Management Errors •

CVSS: 6.5EPSS: 0%CPEs: 100EXPL: 0

A vulnerability in the management interface of Cisco Application Policy Infrastructure Controller (APIC) software could allow an unauthenticated, adjacent attacker to gain unauthorized access on an affected device. The vulnerability is due to a lack of proper access control mechanisms for IPv6 link-local connectivity imposed on the management interface of an affected device. An attacker on the same physical network could exploit this vulnerability by attempting to connect to the IPv6 link-local address on the affected device. A successful exploit could allow the attacker to bypass default access control restrictions on an affected device. Cisco Application Policy Infrastructure Controller (APIC) devices running versions prior to 4.2(0.21c) are affected. • http://www.securityfocus.com/bid/107317 https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-apic-ipv6 • CWE-284: Improper Access Control •

CVSS: 7.8EPSS: 0%CPEs: 38EXPL: 0

A vulnerability in the controller authorization functionality of Cisco Nexus 9000 Series ACI Mode Switch Software could allow an authenticated, local attacker to escalate standard users with root privilege on an affected device. The vulnerability is due to a misconfiguration of certain sudoers files for the bashroot component on an affected device. An attacker could exploit this vulnerability by authenticating to the affected device with a crafted user ID, which may allow temporary administrative access to escalate privileges. A successful exploit could allow the attacker to escalate privileges on an affected device. This Vulnerability has been fixed in version 4.0(1h) Una vulnerabilidad en la funcionalidad de autorización de Cisco Nexus 9000 Series ACI Mode Switch Software puede permitir a un atacante local autenticado escalar usuarios estándares con privilegios root en un dispositivo afectado. • http://www.securityfocus.com/bid/107312 https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20190306-aci-controller-privsec • CWE-16: Configuration •

CVSS: 7.8EPSS: 0%CPEs: 20EXPL: 0

A vulnerability in the DHCPv6 feature of the Cisco Nexus 9000 Series Fabric Switches in Application-Centric Infrastructure (ACI) Mode could allow an unauthenticated, remote attacker to cause the device to run low on system memory, which could result in a Denial of Service (DoS) condition on an affected system. The vulnerability is due to improper memory management when DHCPv6 packets are received on an interface of the targeted device. An attacker could exploit this vulnerability by sending a high number of malicious DHCPv6 packets to be processed by an affected device. A successful exploit could allow the attacker to cause the system to run low on memory, which could cause an eventual reboot of an affected device. The vulnerability only applies to IPv6 protocol packets and not for IPv4 protocol packets. • http://www.securitytracker.com/id/1041348 https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-20180718-nexus-9000-dos • CWE-400: Uncontrolled Resource Consumption •

CVSS: 7.8EPSS: 0%CPEs: 98EXPL: 0

A vulnerability in the CLI parser of Cisco NX-OS Software could allow an authenticated, local attacker to perform a command-injection attack on an affected device. The vulnerability is due to insufficient input validation of command arguments. An attacker could exploit this vulnerability by injecting malicious command arguments into a vulnerable CLI command. A successful exploit could allow the attacker to execute arbitrary commands with root privileges on the affected device. Note: This vulnerability requires that any feature license is uploaded to the device. • http://www.securitytracker.com/id/1041169 https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180620-nx-os-cli-execution • CWE-20: Improper Input Validation CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •