CVE-2017-6865
https://notcve.org/view.php?id=CVE-2017-6865
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC Automation Tool (All versions < V3.0), SIMATIC NET PC-Software (All versions < V14 SP1), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 (TIA Portal) V14 (All versions < V14 SP1), SIMATIC STEP 7 V5.X (All versions < V5.6), SIMATIC WinAC RTX 2010 SP2 (All versions), SIMATIC WinAC RTX F 2010 SP2 (All versions), SIMATIC WinCC (TIA Portal) V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) V14 (All versions < V14 SP1), SIMATIC WinCC V7.2 and prior (All versions), SIMATIC WinCC V7.3 (All versions < V7.3 Update 15), SIMATIC WinCC V7.4 (All versions < V7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (All versions < flexible 2008 SP5), SINAUT ST7CC (All versions installed in conjunction with SIMATIC WinCC < V7.3 Update 15), SINEMA Server (All versions < V14), SINUMERIK 808D Programming Tool (All versions < V4.7 SP4 HF2), SMART PC Access (All versions < V2.3), STEP 7 - Micro/WIN SMART (All versions < V2.3), Security Configuration Tool (SCT) (All versions < V5.0). Specially crafted PROFINET DCP broadcast packets sent to the affected products on a local Ethernet segment (Layer 2) could cause a Denial-of-Service condition of some services. The services require manual restart to recover. Se ha identificado una vulnerabilidad en Primary Setup Tool (PST) (todas las versiones 4.2 HF1), SIMATIC Automation Tool (todas las versiones 3.0), SIMATIC NET PC-software (todas las versiones 14 SP1), SIMATIC PCS 7 Versión 8.1 (todas las versiones), SIMATIC PCS 7 Versión 8.2 (todas las versiones 8.2 SP1), SIMATIC STEP Versión 7 (TIA Portal) Versión 13 (todas las versiones 13 SP2), SIMATIC STEP Versión 7 (TIA Portal) Versión 14 (todas las versiones 14 SP1), SIMATIC STEP 7 Versión 5.x (todas las versiones 5.6), SIMATIC WinAC RTX 2010 SP2 (todas las versiones), SIMATIC WinAC RTX F 2010 SP2 (todas versiones), SIMATIC WinCC (TIA Portal) Versión 13 (todas las versiones 13 SP2), SIMATIC WinCC (TIA Portal) Versión 14 (todas las versiones 14 SP1), SIMATIC WinCC Versión 7.2 y anteriores (todos versiones), SIMATIC WinCC Versión 7.3 (todas las versiones 7.3 actualización 15), SIMATIC WinCC Versión 7.4 (todas las versiones 7.4 SP1 Upd1), SIMATIC WinCC flexible 2008 (todas las versiones anteriores a flexible 2008 SP5), SINAUT ST7CC (todas las versiones instaladas en conjunto con SIMATIC WinCC Versión 7.3 actualización 15), SINEMA Server (todas las versiones 14), SINUMERIK 808D Programming Tool (todas las versiones 4.7 SP4 HF2), SMART PC Access (todas las versiones 2.3), STEP 7 - Micro/WIN SMART (todas las versiones 2.3), Security Configuration Tool (SCT) (todas las versiones 5.0). Los paquetes de difusión PROFINET DCP especialmente creados enviados a los productos afectados en un segmento Ethernet local (Layer 2) podrían causar una condición de denegación de servicio de algunos servicios. • https://cert-portal.siemens.com/productcert/pdf/ssa-275839.pdf https://www.securityfocus.com/bid/98366 • CWE-20: Improper Input Validation •
CVE-2017-6867
https://notcve.org/view.php?id=CVE-2017-6867
A vulnerability was discovered in Siemens SIMATIC WinCC (V7.3 before Upd 11 and V7.4 before SP1), SIMATIC WinCC Runtime Professional (V13 before SP2 and V14 before SP1), SIMATIC WinCC (TIA Portal) Professional (V13 before SP2 and V14 before SP1) that could allow an authenticated, remote attacker who is member of the "administrators" group to crash services by sending specially crafted messages to the DCOM interface. Se detectó una vulnerabilidad en SIMATIC WinCC (versión V7.3 anterior a Upd 11 y versión V7.4 anterior a SP1), SIMATIC WinCC Runtime Professional (versión V13 anterior a SP2 y versión V14 anterior a SP1), SIMATIC WinCC (TIA Portal) Professional (versión V13 anterior a SP2 y versión V14 anterior a SP1) de Siemens, eso podría permitir a un atacante remoto autenticado, quien es miembro del grupo de los "administrators" bloquear los servicios enviando mensajes especialmente diseñados a la interfaz DCOM. • http://www.securityfocus.com/bid/98368 https://cert-portal.siemens.com/productcert/pdf/ssa-523365.pdf https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-156872.pdf • CWE-20: Improper Input Validation CWE-787: Out-of-bounds Write •
CVE-2016-9160
https://notcve.org/view.php?id=CVE-2016-9160
A vulnerability in SIEMENS SIMATIC WinCC (All versions < SIMATIC WinCC V7.2) and SIEMENS SIMATIC PCS 7 (All versions < SIMATIC PCS 7 V8.0 SP1) could allow a remote attacker to crash an ActiveX component or leak parts of the application memory if a user is tricked into clicking on a malicious link under certain conditions. Una vulnerabilidad en SIEMENS SIMATIC WinCC (Todas las versions < SIMATIC WinCC V7.2) y SIEMENS SIMATIC PCS 7 (Todas las versiones < SIMATIC PCS 7 V8.0 SP1) podría permitir a un atacante remoto bloquear un componente ActiveX o filtrar partes de la memoria de aplicación si un usuario es engañado para hacer clic en un enlace malicioso bajo ciertas condiciones. • http://www.securityfocus.com/bid/94825 http://www.securitytracker.com/id/1037435 http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-693129.pdf https://ics-cert.us-cert.gov/advisories/ICSA-16-348-04 • CWE-111: Direct Use of Unsafe JNI CWE-254: 7PK - Security Features •
CVE-2016-7165
https://notcve.org/view.php?id=CVE-2016-7165
A vulnerability has been identified in Primary Setup Tool (PST) (All versions < V4.2 HF1), SIMATIC IT Production Suite (All versions < V7.0 SP1 HFX 2), SIMATIC NET PC-Software (All versions < V14), SIMATIC PCS 7 V7.1 (All versions), SIMATIC PCS 7 V8.0 (All versions), SIMATIC PCS 7 V8.1 (All versions), SIMATIC PCS 7 V8.2 (All versions < V8.2 SP1), SIMATIC STEP 7 (TIA Portal) V13 (All versions < V13 SP2), SIMATIC STEP 7 V5.X (All versions < V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (All versions < V14), SIMATIC WinCC (TIA Portal) Professional V13 (All versions < V13 SP2), SIMATIC WinCC (TIA Portal) Professional V14 (All versions < V14 SP1), SIMATIC WinCC Runtime Professional V13 (All versions < V13 SP2), SIMATIC WinCC Runtime Professional V14 (All versions < V14 SP1), SIMATIC WinCC V7.0 SP2 and earlier versions (All versions < V7.0 SP2 Upd 12), SIMATIC WinCC V7.0 SP3 (All versions < V7.0 SP3 Upd 8), SIMATIC WinCC V7.2 (All versions < V7.2 Upd 14), SIMATIC WinCC V7.3 (All versions < V7.3 Upd 11), SIMATIC WinCC V7.4 (All versions < V7.4 SP1), SIMIT V9.0 (All versions < V9.0 SP1), SINEMA Remote Connect Client (All versions < V1.0 SP3), SINEMA Server (All versions < V13 SP2), SOFTNET Security Client V5.0 (All versions), Security Configuration Tool (SCT) (All versions < V4.3 HF1), TeleControl Server Basic (All versions < V3.0 SP2), WinAC RTX 2010 SP2 (All versions), WinAC RTX F 2010 SP2 (All versions). Unquoted service paths could allow local Microsoft Windows operating system users to escalate their privileges if the affected products are not installed under their default path ("C:\Program Files\*" or the localized equivalent). Se ha identificado una vulnerabilidad en Primary Setup Tool (PST) (todas las versiones anteriores a V4.2 HF1), SIMATIC IT Production Suite (todas las versiones anteriores a V7.0 SP1 HFX 2), SIMATIC NET PC-Software (Todas las versiones anteriores a V14), SIMATIC PCS 7 versión V7.1 (Todas las versiones), SIMATIC PCS 7 versión V8.0 (Todas las versiones), SIMATIC PCS 7 versión V8.1 (Todas las versiones),SIMATIC PCS 7 versión V8.2 (Todas las versiones anteriores a V8.2 SP1), SIMATIC STEP 7 (TIA Portal) versión V13 (Todas las versiones anteriores a V13 SP2), SIMATIC STEP 7 versiones V5.X (Todas las versiones anteriores a V5.5 SP4 HF11), SIMATIC WinCC (TIA Portal) Basic, Comfort, Advanced (Todas las versiones anteriores a V14), SIMATIC WinCC (TIA Portal) Professional versión V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC (TIA Portal) Professional versión V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC Runtime Professional versión V13 (Todas las versiones anteriores a V13 SP2), SIMATIC WinCC Runtime Professional versión V14 (Todas las versiones anteriores a V14 SP1), SIMATIC WinCC versión V7.0 SP2 y anteriores (Todas las versiones anteriores a V7.0 SP2 Upd 12), SIMATIC WinCC versión V7.0 SP3 (Todas las versiones anteriores a V7.0 SP3 Upd 8), SIMATIC WinCC versión V7.2 (Todas las versiones anteriores a V7.2 Upd 14), SIMATIC WinCC versión V7.3 (Todas las versiones anteriores a V7.3 Upd 11), SIMATIC WinCC versión V7.4 (Todas las versiones anteriores a V7.4 SP1), SIMIT versión V9.0 (Todas las versiones anteriores a V9.0 SP1), SINEMA Remote Connect Client (Todas las versiones anteriores a V1.0 SP3), SINEMA Server (Todas las versiones anteriores a V13 SP2), SOFTNET Security Client versión V5.0 (Todas las versiones), Security Configuration Tool (SCT) (Todas las versiones anteriores a V4.3 HF1), TeleControl Server Basic (Todas las versiones anteriores a V3.0 SP2), WinAC RTX 2010 SP2 (Todas las versiones), WinAC RTX F 2010 SP2 (Todas las versiones). Las rutas (path) de servicio sin comillas podrían permitir que los usuarios locales del sistema operativo Microsoft Windows aumenten sus privilegios si los productos afectados no están instalados en su ruta (path) de acceso predeterminada ("C:\Program Files\*" o el equivalente localizado). • http://securityaffairs.co/wordpress/53266/security/cve-2016-7165-siemens.html http://www.securityfocus.com/bid/94158 https://cert-portal.siemens.com/productcert/pdf/ssa-701708.pdf https://ics-cert.us-cert.gov/advisories/ICSA-16-313-02 • CWE-254: 7PK - Security Features CWE-284: Improper Access Control •
CVE-2016-5744
https://notcve.org/view.php?id=CVE-2016-5744
Siemens SIMATIC WinCC 7.0 through SP3 and 7.2 allows remote attackers to read arbitrary WinCC station files via crafted packets. Siemens SIMATIC WinCC 7.0 hasta la versión SP3 y 7.2 permite a atacantes remotos leer archivos de la estación WinCC arbitrarios a través de paquetes manipulados. • http://www.securityfocus.com/bid/92116 http://www.securitytracker.com/id/1036441 http://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-378531.pdf https://ics-cert.us-cert.gov/advisories/ICSA-16-208-01 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •