CVSS: 9.8EPSS: 0%CPEs: 1EXPL: 0

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize user-supplied data provided through the Device-Gateway service port without proper verification. An attacker could provide malicious serialized objects to execute arbitrary code upon deserialization. Delta Electronics InfraSuite Device Master versiones 00.00.01a y anteriores deserializan los datos proporcionados por el usuario a través del puerto de servicio Device-Gateway sin la verificación adecuada. Un atacante podría proporcionar objetos serializados maliciosos para ejecutar código arbitrario tras la deserialización. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation InfraSuite Device Master. • https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07 • CWE-502: Deserialization of Untrusted Data •

CVSS: 9.8EPSS: 0%CPEs: 1EXPL: 0

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior deserialize network packets without proper verification. If the device connects to an attacker-controlled server, the attacker could send maliciously crafted packets that would be deserialized and executed, leading to remote code execution. Delta Electronics InfraSuite Device Master versiones 00.00.01a y anteriores deserializan paquetes de red sin la verificación adecuada. Si el dispositivo se conecta a un servidor controlado por un atacante, éste podría enviar paquetes creados con fines malintencionados que se deserializarían y ejecutarían, lo que provocaría la ejecución remota de código. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Delta Industrial Automation InfraSuite Device Master Device-Monitor. • https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07 • CWE-502: Deserialization of Untrusted Data •

CVSS: 9.8EPSS: 0%CPEs: 1EXPL: 0

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior lack proper authentication for functions that create and modify user groups. An attacker could provide malicious serialized objects that could run these functions without authentication to create a new user and add them to the administrator group. Las versiones 00.00.01a y anteriores de Delta Electronics InfraSuite Device Master carecen de autenticación adecuada para las funciones que crean y modifican grupos de usuarios. Un atacante podría proporcionar objetos serializados maliciosos que podrían ejecutar estas funciones sin autenticación para crear un nuevo usuario y agregarlo al grupo de administradores. This vulnerability allows remote attackers to disclose sensitive information on affected installations of Delta Industrial Automation InfraSuite Device Master. • https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07 • CWE-306: Missing Authentication for Critical Function •

CVSS: 7.5EPSS: 0%CPEs: 1EXPL: 0

Delta Electronics InfraSuite Device Master versions 00.00.01a and prior allow unauthenticated users to trigger the WriteConfiguration method, which could allow an attacker to provide new values for user configuration files such as UserListInfo.xml. This could lead to the changing of administrative passwords. Delta Electronics InfraSuite Device Master versiones 00.00.01a y anteriores permiten a usuarios no autenticados activar el método WriteConfiguration, lo que podría permitir a un atacante proporcionar nuevos valores para archivos de configuración de usuario como UserListInfo.xml. Esto podría dar lugar al cambio de contraseñas administrativas. This vulnerability allows remote attackers to bypass authentication on affected installations of Delta Industrial Automation InfraSuite Device Master. • https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07 • CWE-306: Missing Authentication for Critical Function •

CVSS: 9.8EPSS: 0%CPEs: 1EXPL: 0

The database backup function in Delta Electronics InfraSuite Device Master Versions 00.00.01a and prior lacks proper authentication. An attacker could provide malicious serialized objects which, when deserialized, could activate an opcode for a backup scheduling function without authentication. This function allows the user to designate all function arguments and the file to be executed. This could allow the attacker to start any new process and achieve remote code execution. La función de copia de seguridad de la base de datos en Delta Electronics InfraSuite Device Master versiones 00.00.01a y anteriores carece de autenticación adecuada. • https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-07 • CWE-306: Missing Authentication for Critical Function •