Page 15 of 85 results (0.021 seconds)

CVSS: 5.4EPSS: 0%CPEs: 22EXPL: 0

Reflected Cross-Site Scripting (nonpersistent) allows an attacker to craft a specific URL, which contains Java script that will be executed on the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC client browser. Cross-Site Scripting (XSS) reflejado (no persistente) permite que un atacante manipule una URL específica, que contiene JavaScript que se ejecutará en el navegador del cliente PLC de Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H o BMXP342030H. • https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 5.5EPSS: 0%CPEs: 22EXPL: 0

Remote file inclusion allows an attacker to craft a specific URL referencing the Schneider Electric Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, or BMXP342030H PLC web server, which, when launched, will result in the browser redirecting to a remote file via a Java script loaded with the web page. La inclusión de archivos remotos permite que un atacante manipule una URL específica que referencia al servidor web PLC de Modicon BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H o BMXP342030H, de Schneider Electric, el cual, una vez lanzado, resultará en la redirección del navegador a un archivo remoto mediante un script de Java cargado con la página web. • https://ics-cert.us-cert.gov/advisories/ICSA-15-246-02 • CWE-20: Improper Input Validation CWE-98: Improper Control of Filename for Include/Require Statement in PHP Program ('PHP Remote File Inclusion') •

CVSS: 10.0EPSS: 0%CPEs: 120EXPL: 0

Hard coded accounts exist in Schneider Electric's Modicon Premium, Modicon Quantum, Modicon M340, and BMXNOR0200 controllers in all versions of the communication modules. Existen cuentas embebidas en los controladores Modicon Premium, Modicon Quantum, Modicon M340 y BMXNOR0200, de Schneider Electric, en todas las versiones de los módulos de comunicación. • http://www.securityfocus.com/bid/103542 https://ics-cert.us-cert.gov/advisories/ICSA-18-086-01 https://www.schneider-electric.com/en/download/document/SEVD-2018-081-01 • CWE-798: Use of Hard-coded Credentials •

CVSS: 9.8EPSS: 0%CPEs: 120EXPL: 0

A vulnerability exists in the HTTP request parser in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200 which could allow arbitrary code execution. Existe una vulnerabilidad en Modicon M340, Modicon Premium, Modicon Quantum PLC y BMXNOR0200, de Schneider Electric, que podría permitir la ejecución de código arbitrario. • https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02 • CWE-20: Improper Input Validation •

CVSS: 7.5EPSS: 0%CPEs: 120EXPL: 0

A buffer overflow vulnerability exists in Schneider Electric's Modicon M340, Modicon Premium, Modicon Quantum PLC, BMXNOR0200. The buffer overflow vulnerability is caused by the length of the source string specified (instead of the buffer size) as the number of bytes to be copied. Existe una vulnerabilidad de desbordamiento de búfer en Modicon M340, Modicon Premium, Modicon Quantum PLC y BMXNOR0200, de Schneider Electric. La vulnerabilidad de desbordamiento de búfer se provoca por el tamaño de la cadena de origen especificada (en lugar del tamaño del búfer) como número de bytes que deben copiarse. • https://www.schneider-electric.com/en/download/document/SEVD-2018-081-02 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •