CVE-2019-18858
https://notcve.org/view.php?id=CVE-2019-18858
CODESYS 3 web server before 3.5.15.20, as distributed with CODESYS Control runtime systems, has a Buffer Overflow. El servidor web CODESYS 3 versiones anteriores a la versión 3.5.15.20, distribuido con los sistemas de tiempo de ejecución CODESYS Control, tiene un desbordamiento de búfer. • https://customers.codesys.com/fileadmin/data/customers/security/2019/Advisory2019-10_CDS-68341.pdf https://www.tenable.com/security/research/tra-2019-48 • CWE-120: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') •
CVE-2019-13542
https://notcve.org/view.php?id=CVE-2019-13542
3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, all versions 3.5.11.0 to 3.5.15.0, allows an attacker to send crafted requests from a trusted OPC UA client that cause a NULL pointer dereference, which may trigger a denial-of-service condition. 3S-Smart Software Solutions GmbH CODESYS V3 OPC UA Server, todas las versiones desde 3.5.11.0 hasta 3.5.15.0, permite a un atacante enviar peticiones diseñadas desde un cliente OPC UA confiable que causa una desreferencia del puntero NULL, lo que puede desencadenar una condición de denegación de servicio. • https://www.us-cert.gov/ics/advisories/icsa-19-255-04 • CWE-476: NULL Pointer Dereference •
CVE-2019-9009
https://notcve.org/view.php?id=CVE-2019-9009
An issue was discovered in 3S-Smart CODESYS before 3.5.15.0 . Crafted network packets cause the Control Runtime to crash. Se descubrió un problema en 3S-Smart CODESYS versiones anteriores a 3.5.15.0. Unos paquetes de red diseñados causan que el Control Runtime se bloquee. • https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12941&token=50fabe3870c7bdc41701eb1799dddeec103de40c&download= https://www.us-cert.gov/ics/advisories/icsa-19-255-05 • CWE-755: Improper Handling of Exceptional Conditions •
CVE-2019-9008
https://notcve.org/view.php?id=CVE-2019-9008
An issue was discovered in 3S-Smart CODESYS V3 through 3.5.12.30. A user with low privileges can take full control over the runtime. Se detectó un problema en 3S-Smart CODESYS V3 versiones hasta 3.5.12.30. Un usuario con pocos privilegios puede tomar el control total sobre el tiempo de ejecución. • https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12939&token=5b93f0d95a68ff7461d2c249d8da00f16b8f9987&download= https://www.codesys.com https://www.us-cert.gov/ics/advisories/icsa-19-255-03 • CWE-732: Incorrect Permission Assignment for Critical Resource •
CVE-2019-13548
https://notcve.org/view.php?id=CVE-2019-13548
CODESYS V3 web server, all versions prior to 3.5.14.10, allows an attacker to send specially crafted http or https requests which could cause a stack overflow and create a denial-of-service condition or allow remote code execution. El servidor web de CODESYS V3, todas las versiones anteriores a 3.5.14.10, permite a un atacante enviar peticiones http o https especialmente diseñadas que podrían causar un desbordamiento de la pila y crear una condición de denegación de servicio o permitir la ejecución de código remota. • https://www.us-cert.gov/ics/advisories/icsa-19-255-01 • CWE-121: Stack-based Buffer Overflow CWE-787: Out-of-bounds Write •