CVE-2018-0019 – Junos: Denial of service vulnerability in SNMP MIB-II subagent daemon (mib2d).
https://notcve.org/view.php?id=CVE-2018-0019
11 Apr 2018 — A vulnerability in Junos OS SNMP MIB-II subagent daemon (mib2d) may allow a remote network based attacker to cause the mib2d process to crash resulting in a denial of service condition (DoS) for the SNMP subsystem. While a mib2d process crash can disrupt the network monitoring via SNMP, it does not impact routing, switching or firewall functionalities. SNMP is disabled by default on devices running Junos OS. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D76; 12.3 version... • http://www.securitytracker.com/id/1040787 • CWE-20: Improper Input Validation •

CVE-2018-0022 – Junos OS: Mbuf leak due to processing MPLS packets in VPLS network.
https://notcve.org/view.php?id=CVE-2018-0022
11 Apr 2018 — A Junos device with VPLS routing-instances configured on one or more interfaces may be susceptible to an mbuf leak when processing a specific MPLS packet. Approximately 1 mbuf is leaked per each packet processed. The number of mbufs is platform dependent. The following command provides the number of mbufs that are currently in use and maximum number of mbufs that can be allocated on a platform: > show system buffers 2437/3143/5580 mbufs in use (current/cache/total) Once the device runs out of mbufs it will ... • http://www.securityfocus.com/bid/103740 • CWE-400: Uncontrolled Resource Consumption •

CVE-2014-3413
https://notcve.org/view.php?id=CVE-2014-3413
05 Apr 2018 — The MySQL server in Juniper Networks Junos Space before 13.3R1.8 has an unspecified account with a hardcoded password, which allows remote attackers to obtain sensitive information and consequently obtain administrative control by leveraging database access. El servidor MySQL en Juniper Networks Junos Space, en versiones anteriores a la 13.3R1.8, tiene una cuenta sin especificar con una contraseña embebida. Esto permite que atacantes remotos obtengan información sensible y, consecuentemente, obtengan contro... • https://kb.juniper.net/InfoCenter/index?page=content&id=JSA10627 • CWE-798: Use of Hard-coded Credentials •

CVE-2017-3145 – Improper fetch cleanup sequencing in the resolver can cause named to crash
https://notcve.org/view.php?id=CVE-2017-3145
16 Jan 2018 — BIND was improperly sequencing cleanup operations on upstream recursion fetch contexts, leading in some cases to a use-after-free error that can trigger an assertion failure and crash in named. Affects BIND 9.0.0 to 9.8.x, 9.9.0 to 9.9.11, 9.10.0 to 9.10.6, 9.11.0 to 9.11.2, 9.9.3-S1 to 9.9.11-S1, 9.10.5-S1 to 9.10.6-S1, 9.12.0a1 to 9.12.0rc1. BIND secuenciaba incorrectamente las operaciones de limpieza en contextos fetch de recursión ascendente, lo que conduce en algunos casos a un error de uso de memoria ... • http://www.securityfocus.com/bid/102716 • CWE-416: Use After Free •

CVE-2018-0002 – MX series, SRX series: Junos OS: Denial of service vulnerability in Flowd on devices with ALG enabled.
https://notcve.org/view.php?id=CVE-2018-0002
10 Jan 2018 — On SRX Series and MX Series devices with a Service PIC with any ALG enabled, a crafted TCP/IP response packet processed through the device results in memory corruption leading to a flowd daemon crash. Sustained crafted response packets lead to repeated crashes of the flowd daemon which results in an extended Denial of Service condition. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D60 on SRX series; 12.3X48 versions prior to 12.3X48-D35 on SRX series; 14.1 versions prio... • http://www.securitytracker.com/id/1040178 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVE-2018-0004 – Junos OS: Kernel Denial of Service Vulnerability
https://notcve.org/view.php?id=CVE-2018-0004
10 Jan 2018 — A sustained sequence of different types of normal transit traffic can trigger a high CPU consumption denial of service condition in the Junos OS register and schedule software interrupt handler subsystem when a specific command is issued to the device. This affects one or more threads and conversely one or more running processes running on the system. Once this occurs, the high CPU event(s) affects either or both the forwarding and control plane. As a result of this condition the device can become inaccessi... • http://www.securitytracker.com/id/1040183 • CWE-400: Uncontrolled Resource Consumption •

CVE-2018-0007
https://notcve.org/view.php?id=CVE-2018-0007
10 Jan 2018 — An unauthenticated network-based attacker able to send a maliciously crafted LLDP packet to the local segment, through a local segment broadcast, may be able to cause a Junos device to enter an improper boundary check condition allowing a memory corruption to occur, leading to a denial of service. Further crafted packets may be able to sustain the denial of service condition. Score: 6.5 MEDIUM (CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H) Further, if the attacker is authenticated on the target device recei... • http://www.securitytracker.com/id/1040181 • CWE-77: Improper Neutralization of Special Elements used in a Command ('Command Injection') CWE-94: Improper Control of Generation of Code ('Code Injection') CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVE-2018-0008 – Junos OS: commit script may allow unauthenticated root login upon reboot
https://notcve.org/view.php?id=CVE-2018-0008
10 Jan 2018 — An unauthenticated root login may allow upon reboot when a commit script is used. A commit script allows a device administrator to execute certain instructions during commit, which is configured under the [system scripts commit] stanza. Certain commit scripts that work without a problem during normal commit may cause unexpected behavior upon reboot which can leave the system in a state where root CLI login is allowed without a password due to the system reverting to a "safe mode" authentication state. Lastl... • http://www.securitytracker.com/id/1040186 • CWE-287: Improper Authentication •

CVE-2018-0009 – SRX Series: Firewall bypass vulnerability when UUID with leading zeros is configured.
https://notcve.org/view.php?id=CVE-2018-0009
10 Jan 2018 — On Juniper Networks SRX series devices, firewall rules configured to match custom application UUIDs starting with zeros can match all TCP traffic. Due to this issue, traffic that should have been blocked by other rules is permitted to flow through the device resulting in a firewall bypass condition. Affected releases are Juniper Networks Junos OS: 12.1X46 versions prior to 12.1X46-D71 on SRX series; 12.3X48 versions prior to 12.3X48-D55 on SRX series; 15.1X49 versions prior to 15.1X49-D100 on SRX series. En... • http://www.securityfocus.com/bid/102491 •

CVE-2018-0010
https://notcve.org/view.php?id=CVE-2018-0010
10 Jan 2018 — A vulnerability in the Juniper Networks Junos Space Security Director allows a user who does not have SSH access to a device to reuse the URL that was created for another user to perform SSH access. Affected releases are all versions of Junos Space Security Director prior to 17.2R1. Una vulnerabilidad en Juniper Networks Junos Space Security Director permite a un usuario que no tiene acceso SSH a un dispositivo reutilizar la URL que se había creado para otro usuario para sí tener acceso SSH. Las distribucio... • https://kb.juniper.net/JSA10840 • CWE-269: Improper Privilege Management •