CVE-2022-36970 – AVEVA Edge APP File Insufficient UI Warning Remote Code Execution Vulnerability
https://notcve.org/view.php?id=CVE-2022-36970
This vulnerability allows remote attackers to execute arbitrary code on affected installations of AVEVA Edge 20.0 Build: 4201.2111.1802.0000 Service Pack 2. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the processing of APP files. Crafted data in a APP file can cause the application to execute arbitrary Visual Basic scripts. The user interface fails to provide sufficient indication of the hazard. • https://www.aveva.com/content/dam/aveva/documents/support/cyber-security-updates/SecurityBulletin_AVEVA-2022-005.pdf https://www.zerodayinitiative.com/advisories/ZDI-22-1129 • CWE-356: Product UI does not Warn User of Unsafe Actions •
CVE-2015-0999
https://notcve.org/view.php?id=CVE-2015-0999
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 store cleartext OPC User credentials in a configuration file, which allows local users to obtain sensitive information by reading this file. Schneider Electric InduSoft Web Studio anterior a 7.1.3.4 SP3 Patch 4 e InTouch Machine Edition 2014 anterior a 7.1.3.4 SP3 Patch 4 almacenan las credenciales de usuarios OPC en texto claro en un fichero de configuración, lo que permite a usuarios locales obtener información sensible mediante la lectura de este fichero. • http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-054-01 http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-054-02 https://ics-cert.us-cert.gov/advisories/ICSA-15-085-01 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •
CVE-2015-0996
https://notcve.org/view.php?id=CVE-2015-0996
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 rely on a hardcoded cleartext password to control read access to Project files and Project Configuration files, which makes it easier for local users to obtain sensitive information by discovering this password. Schneider Electric InduSoft Web Studio anterior a 7.1.3.4 SP3 Patch 4 e InTouch Machine Edition 2014 anterior a 7.1.3.4 SP3 Patch 4 dependen de una contraseña de texto claro embebida para controlar el acceso de lectura a los ficheros de proyectos y de la configuración de proyectos, lo que facilita a usuarios locales obtener información sensible mediante el descubrimiento de esta contraseña. • http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-054-01 http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-054-02 https://ics-cert.us-cert.gov/advisories/ICSA-15-085-01 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •
CVE-2015-0998
https://notcve.org/view.php?id=CVE-2015-0998
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 transmit cleartext credentials, which allows remote attackers to obtain sensitive information by sniffing the network. Schneider Electric InduSoft Web Studio anterior a 7.1.3.4 SP3 Patch 4 y InTouch Machine Edition 2014 anterior a 7.1.3.4 SP3 Patch 4 transmiten credenciales en texto claro, lo que permite a atacantes remotos obtener información sensible mediante la captura de trafico de la red. • http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-054-01 http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-054-02 https://ics-cert.us-cert.gov/advisories/ICSA-15-085-01 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •
CVE-2015-0997
https://notcve.org/view.php?id=CVE-2015-0997
Schneider Electric InduSoft Web Studio before 7.1.3.4 SP3 Patch 4 and InTouch Machine Edition 2014 before 7.1.3.4 SP3 Patch 4 provide an HMI user interface that lists all valid usernames, which makes it easier for remote attackers to obtain access via a brute-force password-guessing attack. Schneider Electric InduSoft Web Studio anterior a 7.1.3.4 SP3 Patch 4 y InTouch Machine Edition 2014 anterior a 7.1.3.4 SP3 Patch 4 proporcionan una interfaz de usuario HMI que lista todos los nombres de usuario válidos, lo que facilita a atacantes remotos obtener el acceso a través de un ataque de adivinación de contraseñas de fuerza bruta. • http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-054-01 http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2015-054-02 https://ics-cert.us-cert.gov/advisories/ICSA-15-085-01 • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •