CVSS: 7.5EPSS: 7%CPEs: 5EXPL: 0

In CommCell in Commvault before 14.68, 15.x before 15.58, 16.x before 16.44, 17.x before 17.29, and 18.x before 18.13, Directory Traversal can occur such that an attempt to view a log file can instead view a file outside of the log-files folder. En CommCell en Commvault versiones anteriores a 14.68, versiones 15.x anteriores a 15.58, versiones 16.x anteriores a 16.44, versiones 17.x anteriores a 17.29 y versiones 18.x anteriores a 18.13, Un Salto de Directorio puede ocurrir de manera que un intento de visualizar un archivo de registro puede en su lugar visualizar un archivo fuera de la carpeta log-files • http://kb.commvault.com/article/63264 • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 10.0EPSS: 6%CPEs: 6EXPL: 2

A Command Injection issue was discovered in ContentStore/Base/CVDataPipe.dll in Commvault before v11 SP6. A certain message parsing function inside the Commvault service does not properly validate the input of an incoming string before passing it to CreateProcess. As a result, a specially crafted message can inject commands that will be executed on the target operating system. Exploitation of this vulnerability does not require authentication and can lead to SYSTEM level privilege on any system running the cvd daemon. This is a different vulnerability than CVE-2017-3195. • https://github.com/securifera/CVE-2017-18044-Exploit https://github.com/rapid7/metasploit-framework/pull/9340 https://github.com/rapid7/metasploit-framework/pull/9389 https://www.securifera.com/advisories/sec-2017-0001 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •

CVSS: 10.0EPSS: 3%CPEs: 7EXPL: 1

Commvault Edge Communication Service (cvd) prior to version 11 SP7 or version 11 SP6 with hotfix 590 is prone to a stack-based buffer overflow vulnerability that could lead to arbitrary code execution with administrative privileges. Commvault Edge Communication Service (cvd) en su versión 11 SP7 o la versión 11 SP6 con hotfix 590 es vulnerable a un desbordamiento de búfer basado en pila, lo que puede conducir a una ejecución de código arbitrario con privilegios de administrador. • https://www.exploit-db.com/exploits/41823 http://kb.commvault.com/article/SEC0013 http://redr2e.com/commvault-edge-cve-2017-3195 http://www.securityfocus.com/bid/96941 https://www.kb.cert.org/vuls/id/214283 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer CWE-121: Stack-based Buffer Overflow •

CVSS: 10.0EPSS: 0%CPEs: 1EXPL: 0

The Web Console in Commvault Edge Server 10 R2 allows remote attackers to execute arbitrary OS commands via crafted serialized data in a cookie. La Web Console en Commvault Edge Server 10 R2 permite a atacantes remotos ejecutar comandos OS arbitrarios a través de datos serializados en una cookie. • http://www.kb.cert.org/vuls/id/866432 • CWE-78: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection') •