Page 2 of 258 results (0.012 seconds)

CVSS: 4.6EPSS: 0%CPEs: 1EXPL: 0

16 Apr 2025 — Overview The software does not neutralize or incorrectly neutralize user-controllable input before it is placed in output that is used as a web page that is served to other users. (CWE-79) Description Hitachi Vantara Pentaho Business Analytics Server prior to versions 10.2.0.2, including 9.3.x and 8.3.x, allow a malicious URL to inject content into the Analyzer plugin interface. Impact Once the malicious script is injected, the attacker can perform a variety of malicious activities. The attacker could trans... • https://support.pentaho.com/hc/en-us/articles/35782541484045--Resolved-Hitachi-Vantara-Pentaho-Business-Analytics-Server-Improper-Neutralization-of-Input-During-Web-Page-Generation-Cross-site-Scripting-Versions-before-10-2-0-2-including-9-3-x-Impacted-CVE-2025-24909 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 6.8EPSS: 0%CPEs: 1EXPL: 0

16 Apr 2025 — Overview The product uses external input to construct a pathname that should be within a restricted directory, but it does not properly neutralize '.../...//' (doubled triple dot slash) sequences that can resolve to a location that is outside of that directory. (CWE-35) Description Hitachi Vantara Pentaho Data Integration & Analytics versions before 10.2.0.2, including 9.3.x and 8.3.x, do not sanitize a user input used as a file path through the UploadFile service. Impact This allows attackers to traverse t... • https://support.pentaho.com/hc/en-us/articles/35783399569421--Resolved-Hitachi-Vantara-Pentaho-Data-Integration-Analytics-Path-Traversal-Versions-before-10-2-0-2-including-9-3-x-Impacted-CVE-2025-24908 • CWE-35: Path Traversal: '.../ •

CVSS: 9.1EPSS: 0%CPEs: 1EXPL: 0

16 Apr 2025 — Overview The product receives input from an upstream component, but it does not restrict or incorrectly restricts the input before it is used as an identifier for a resource that may be outside the intended sphere of control. (CWE-99) Description Hitachi Vantara Pentaho Data Integration & Analytics versions before 10.2.0.2, including 9.3.x and 8.3.x, do not restrict JNDI identifiers during the creation of platform data sources. Impact An attacker could gain access to or modify sensitive data or system resou... • https://https://support.pentaho.com/hc/en-us/articles/35771876077709--Resolved-Hitachi-Vantara-Pentaho-Data-Integration-Analytics-Improper-Control-of-Resource-Identifiers-Resource-Injection-Versions-before-10-2-0-2-including-9-3-x-Impacted-CVE-2025-0756 • CWE-99: Improper Control of Resource Identifiers ('Resource Injection') •

CVSS: 4.6EPSS: 0%CPEs: 1EXPL: 0

16 Apr 2025 — Overview The software does not neutralize or incorrectly neutralize user-controllable input before it is placed in output that is used as a web page that is served to other users. (CWE-79) Description Hitachi Vantara Pentaho Business Analytics Server prior to versions 10.2.0.2, including 9.3.x and 8.3.x, allow a malicious URL to inject content into the Analyzer plugin interface. Impact Once the malicious script is injected, the attacker can perform a variety of malicious activities. The attacker could trans... • https://support.pentaho.com/hc/en-us/articles/35781038882445--Resolved-Hitachi-Vantara-Pentaho-Business-Analytics-Server-Improper-Neutralization-of-Input-During-Web-Page-Generation-Cross-site-Scripting-Versions-before-10-2-0-2-including-9-3-x-Impacted-CVE-2025-0757 • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 6.1EPSS: 0%CPEs: 1EXPL: 0

16 Apr 2025 — Overview The product specifies permissions for a security-critical resource in a way that allows that resource to be read or modified by unintended actors. (CWE-732) Description Hitachi Vantara Pentaho Business Analytics Server prior to versions 10.2.0.2, including 9.3.x and 8.3.x, is installed with Karaf JMX beans enabled and accessible by default. Impact When the vulnerability is leveraged, a user with local execution privileges can access functionality exposed by Karaf beans contained in the product. • https://support.pentaho.com/hc/en-us/articles/35781318194061--Resolved-Hitachi-Vantara-Pentaho-Business-Analytics-Server-Incorrect-Permission-Assignment-for-Critical-Resource-Versions-before-10-2-0-2-including-9-3-x-Impacted-CVE-2025-0758 • CWE-732: Incorrect Permission Assignment for Critical Resource •

CVSS: 6.5EPSS: 0%CPEs: 2EXPL: 0

25 Mar 2025 — The TRMTracker web application is vulnerable to LDAP injection attack potentially allowing an attacker to inject code into a query and execute remote commands that can read and update data on the website. • https://publisher.hitachienergy.com/preview?DocumentID=8DBD000210&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-90: Improper Neutralization of Special Elements used in an LDAP Query ('LDAP Injection') •

CVSS: 6.4EPSS: 0%CPEs: 2EXPL: 0

25 Mar 2025 — The TRMTracker web application is vulnerable to reflected Cross-site scripting attack. The application allows client-side code injection that might be used to compromise the confidentiality and integrity of the system. • https://publisher.hitachienergy.com/preview?DocumentID=8DBD000210&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-79: Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') •

CVSS: 8.7EPSS: 0%CPEs: 1EXPL: 0

25 Mar 2025 — A vulnerability exists in RTU IEC 61850 client and server functionality that could impact the availability if renegotiation of an open IEC61850 TLS connection takes place in specific timing situations, when IEC61850 communication is active. Precondition is that IEC61850 as client or server are configured using TLS on RTU500 device. It affects the CMU the IEC61850 stack is configured on. • https://publisher.hitachienergy.com/preview?DocumentId=8DBD000207&languageCode=en&Preview=true • CWE-820: Missing Synchronization •

CVSS: 6.4EPSS: 0%CPEs: 2EXPL: 0

25 Mar 2025 — A Host Header Injection vulnerability in TRMTracker application may allow an attacker by modifying the host header value in an HTTP request to leverage multiple attack vectors, including defacing the site content through web-cache poisoning. • https://publisher.hitachienergy.com/preview?DocumentID=8DBD000210&LanguageCode=en&DocumentPartId=&Action=Launch • CWE-74: Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection') •

CVSS: 8.7EPSS: 0%CPEs: 3EXPL: 0

25 Mar 2025 — A vulnerability exists in RTU500 IEC 60870-5-104 controlled station functionality and IEC 61850 functionality, that allows an attacker performing a specific attack sequence to restart the affected CMU. This vulnerability only applies, if secure communication using IEC 62351-3 (TLS) is enabled. • https://publisher.hitachienergy.com/preview?DocumentId=8DBD000207&languageCode=en&Preview=true •