Page 2 of 13 results (0.007 seconds)

CVSS: 7.8EPSS: 0%CPEs: 3EXPL: 0

Inclusion of Functionality from Untrusted Control Sphere vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes. Una vulnerabilidad de Inclusión de Funcionalidad de la Esfera de Control No Confiable en ICONICS GENESIS64 versiones 10.97.1 y anteriores y Mitsubishi Electric MC Works64 versiones 4.04E (10.95.210.01) y anteriores permite a un atacante no autenticado ejecutar un código malicioso arbitrario al conllevar a un usuario a cargar un archivo de pantalla de monitoreo que incluye códigos de script maliciosos This vulnerability allows remote attackers to execute arbitrary code on affected installations of ICONICS GENESIS64. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of GDFX files. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute code in the context of the ICONICS_ADMIN user. • https://jvn.jp/vu/JVNVU96480474/index.html https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf • CWE-829: Inclusion of Functionality from Untrusted Control Sphere •

CVSS: 7.8EPSS: 0%CPEs: 3EXPL: 0

Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes. Una vulnerabilidad de Deserialización de Datos No Confiables en ICONICS GENESIS64 versiones 10.97.1 y anteriores y Mitsubishi Electric MC Works64 versiones 4.04E (10.95.210.01) y anteriores permite a un atacante no autenticado ejecutar un código malicioso arbitrario al conllevar a un usuario a cargar un archivo de pantalla de monitoreo que incluye códigos XAML maliciosos This vulnerability allows remote attackers to execute arbitrary code on affected installations of ICONICS GENESIS64. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of GDFX files. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current process. • https://jvn.jp/vu/JVNVU96480474/index.html https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf • CWE-502: Deserialization of Untrusted Data •

CVSS: 7.5EPSS: 0%CPEs: 2EXPL: 0

Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in ICONICS GENESIS64 versions 10.97 to 10.97.1 allows a remote unauthenticated attacker to access to arbitrary files in the GENESIS64 server and disclose information stored in the files by embedding a malicious URL parameter in the URL of the monitoring screen delivered to the GENESIS64 mobile monitoring application and accessing the monitoring screen. La vulnerabilidad de Limitación Inapropiada de un Nombre de Ruta a un Directorio Restringido ("Salto de Ruta") en ICONICS GENESIS64 versiones 10.97 a 10.97.1, permite a un atacante remoto no autenticado acceder a archivos arbitrarios en el servidor de GENESIS64 y divulgar información almacenada en los archivos al insertar un parámetro de URL malicioso en la URL de la pantalla de monitorización entregada a la aplicación de monitorización móvil GENESIS64 y acceder a la pantalla de monitorización This vulnerability allows remote attackers to disclose sensitive information on affected installations of ICONICS GENESIS64. Authentication is not required to exploit this vulnerability. The specific flaw exists within the colorpalletes endpoint. When parsing the path parameter, the process does not properly validate a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to disclose stored credentials, leading to further compromise. • https://jvn.jp/vu/JVNVU96480474/index.html https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf • CWE-22: Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') •

CVSS: 9.8EPSS: 0%CPEs: 5EXPL: 0

Incomplete List of Disallowed Inputs vulnerability in Mitsubishi Electric MC Works64 versions 4.00A (10.95.201.23) to 4.04E (10.95.210.01), ICONICS GENESIS64 versions 10.95.3 to 10.97, ICONICS Hyper Historian versions 10.95.3 to 10.97, ICONICS AnalytiX versions 10.95.3 to 10.97 and ICONICS MobileHMI versions 10.95.3 to 10.97 allows a remote unauthenticated attacker to bypass the authentication of MC Works64, GENESIS64, Hyper Historian, AnalytiX and MobileHMI, and gain unauthorized access to the products, by sending specially crafted WebSocket packets to FrameWorX server, one of the functions of the products. Una vulnerabilidad "Incomplete List of Disallowed Inputs" en Mitsubishi Electric MC Works64 versiones 4.00A (10.95.201.23) a 4.04E (10.95.210.01), ICONICS GENESIS64 versiones 10.95.3 a 10.97, ICONICS Hyper Historian versiones 10.95.3 a 10.97, ICONICS AnalytiX versiones 10.95.3 a 10.97 e ICONICS MobileHMI versiones 10. 95.3 a 10.97 permite a un atacante remoto no autenticado omitir la autenticación de MC Works64, GENESIS64, Hyper Historian, AnalytiX y MobileHMI, y conseguir acceso no autorizado a los productos, mediante el envío de paquetes WebSocket especialmente diseñados al servidor FrameWorX, una de las funciones de los productos • https://jvn.jp/vu/JVNVU95403720/index.html https://www.cisa.gov/uscert/ics/advisories/icsa-22-020-01 https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-026_en.pdf •

CVSS: 5.5EPSS: 0%CPEs: 2EXPL: 0

Plaintext Storage of a Password vulnerability in Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior and ICONICS GENESIS64 versions 10.90 to 10.97 allows a local authenticated attacker to gain authentication information and to access the database illegally. This is because when configuration information of GridWorX, a database linkage function of GENESIS64 and MC Works64, is exported to a CSV file, the authentication information is saved in plaintext, and an attacker who can access this CSV file can gain the authentication information. Una vulnerabilidad de almacenamiento de texto plano de una contraseña en Mitsubishi Electric MC Works64 versiones 4.04E (10.95.210.01) y anteriores y en ICONICS GENESIS64 versiones 10.90 a 10.97, permite a un atacante local autenticado conseguir información de autenticación y acceder a la base de datos de forma ilegal. Esto es debido a que cuando la información de configuración de GridWorX, una función de enlace de bases de datos de GENESIS64 y MC Works64, es exportada a un archivo CSV, la información de autenticación es guardada en texto plano, y un atacante que pueda acceder a este archivo CSV puede conseguir la información de autenticación • https://jvn.jp/vu/JVNVU95403720/index.html https://us-cert.cisa.gov/ics/advisories/icsa-22-020-01 https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2021-027_en.pdf • CWE-312: Cleartext Storage of Sensitive Information •