
CVE-2020-24506
https://notcve.org/view.php?id=CVE-2020-24506
09 Jun 2021 — Out of bound read in a subsystem in the Intel(R) CSME versions before 12.0.81, 13.0.47, 13.30.17, 14.1.53 and 14.5.32 may allow a privileged user to potentially enable information disclosure via local access. Una lectura fuera de límites de un subsistema en Intel® CSME versiones anteriores a 12.0.81, 13.0.47, 13.30.17, 14.1.53 y 14.5.32 puede permitir a un usuario privilegiado habilitar potencialmente una divulgación de información por medio de un acceso local • https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf • CWE-125: Out-of-bounds Read •

CVE-2020-8703
https://notcve.org/view.php?id=CVE-2020-8703
09 Jun 2021 — Improper buffer restrictions in a subsystem in the Intel(R) CSME versions before 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32 and 15.0.22 may allow a privileged user to potentially enable escalation of privilege via local access. Unas restricciones de búfer inapropiadas en un subsistema en Intel® CSME versiones anteriores a 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32 y 15.0.22 pueden permitir a un usuario privilegiado habilitar potencialmente una es... • https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVE-2020-24507
https://notcve.org/view.php?id=CVE-2020-24507
09 Jun 2021 — Improper initialization in a subsystem in the Intel(R) CSME versions before 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32, 13.50.11 and 15.0.22 may allow a privileged user to potentially enable information disclosure via local access. Una inicialización inapropiada en un subsistema en Intel® CSME versiones anteriores a 11.8.86, 11.12.86, 11.22.86, 12.0.81, 13.0.47, 13.30.17, 14.1.53, 14.5.32, 13.50.11 y 15.0.22 puede habilitar a un usuario privilegiado para permitir potencialment... • https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf • CWE-665: Improper Initialization •

CVE-2020-24513 – hw: information disclosure on some Intel Atom processors
https://notcve.org/view.php?id=CVE-2020-24513
09 Jun 2021 — Domain-bypass transient execution vulnerability in some Intel Atom(R) Processors may allow an authenticated user to potentially enable information disclosure via local access. Una vulnerabilidad en la ejecución transitoria de omisión de dominios en algunos procesadores Intel Atom® puede permitir a un usuario autenticado permitir potencialmente una divulgación de información por medio de un acceso local A potential domain bypass transient execution vulnerability was discovered on some Intel Atom® processors ... • https://cert-portal.siemens.com/productcert/pdf/ssa-309571.pdf • CWE-200: Exposure of Sensitive Information to an Unauthorized Actor •