Page 2 of 9 results (0.010 seconds)

CVSS: 7.8EPSS: 0%CPEs: 1EXPL: 0

The HTTP application on Mitsubishi Electric MELSEC FX3G PLC devices before April 2015 allows remote attackers to cause a denial of service (device outage) via a long parameter. Aplicación HTTP en dispositivos Mitsubishi Electric MELSEC FX3G PLC en versiones anteriores a April 2015, permite a atacantes remotos provocar una denegación de servicio (interrupción del dispositivo) a través de un parámetro largo. Mitsubishi Melsec FX3G-24M suffers from a denial of service vulnerability. • https://ics-cert.us-cert.gov/advisories/ICSA-15-146-01 • CWE-399: Resource Management Errors •

CVSS: 10.0EPSS: 94%CPEs: 3EXPL: 2

Multiple buffer overflows in ActUWzd.dll 1.0.0.1 in Mitsubishi MX Component 3, as distributed in Citect CitectFacilities 7.10 and CitectScada 7.10r1, allow remote attackers to execute arbitrary code via a long string, as demonstrated by a long WzTitle property value to a certain ActiveX control. Múltiples desbordamientos de búfer en ActUWzd.dll v1.0.0.1 en Mitsubishi MX componente 3, que distribuye en CitectFacilities Citect v7.10 y CitectSCADA v7.10r1, permite a atacantes remotos ejecutar código arbitrario a través de una cadena larga, como lo demuestra con un valor largo de la propiedad WzTitle a un determinado ActiveX control. • https://www.exploit-db.com/exploits/24886 http://www.exploit-db.com/exploits/24886 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 4.6EPSS: 0%CPEs: 2EXPL: 0

Buffer overflow in an unspecified third-party component in the Batch module for Schneider Electric CitectSCADA before 7.20 and Mitsubishi MX4 SCADA before 7.20 allows local users to execute arbitrary code via a long string in a login sequence. Desbordamiento de búfer en un componente de terceros no especificado en el módulo de ejecución por lote para Schneider Electric CitectSCADA anterior a v7.20 y Mitsubishi MX4 SCADA anterior a v7.20 permite a usuarios locales ejecutar código arbitrario a través de una cadena larga en una secuencia de acceso. • http://secunia.com/advisories/46779 http://secunia.com/advisories/46786 http://www.citect.com/citectscada-batch http://www.osvdb.org/76937 http://www.securitytracker.com/id?1026306 http://www.us-cert.gov/control_systems/pdf/ICSA-11-279-02.pdf https://my.mitsubishi-automation.com/downloads_show.php?portal_id=1&doc_type=safety&scat=2&sstr=MX4%2CSCADA • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •

CVSS: 7.8EPSS: 1%CPEs: 2EXPL: 0

servlet/MIMEReceiveServlet in the web controller for Mitsubishi Electric GB-50 and GB-50A air-conditioning control systems allows remote attackers to cause a denial of service (air-conditioning outage) via an XML document containing a setRequest command. servlet/MIMEReceiveServlet en el controlador web para los sistemas de control de aire acondicionado Mitsubishi Electric GB-50 y GB-50A permite a atacantes remotos provocar la Denegación de Servicio (air-conditioning outage) mediante un documento XML que contiene un comando setRequest. • http://securityreason.com/securityalert/3794 http://www.securityfocus.com/archive/1/483862/2008-03-21/threaded http://www.securityfocus.com/archive/1/489970/100/0/threaded http://www.securityfocus.com/bid/28406 https://exchange.xforce.ibmcloud.com/vulnerabilities/41503 •