Page 2 of 8 results (0.005 seconds)

CVSS: 4.0EPSS: 0%CPEs: 20EXPL: 0

An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. Because of an Incorrect Permission Assignment for Critical Resource, users with administrator privileges may be able to remove all administrative users requiring a factory reset to restore ancillary web server function. Exploitation of this vulnerability will still allow the affected device to function in its capacity as a controller. Ha sido descubierto un problema en controlador Rockwell Automation Allen-Bradley MicroLogix 1100, 1763-L16AWA, Serie A y B, Versión 14.000 y versiones anteriores; 1763-L16BBB, Serie A y B, Versión 14.000 y versiones anteriores; 1763-L16BWA, Serie A y B, Versión 14.000 y versiones anteriores; y 1763-L16DWD, Serie A y B, Versión 14.000 y versiones anteriores. Debido a una asignación de permisos incorrecta para recursos críticos, los usuarios con privilegios de administrador pueden eliminar todos los usuarios administrativos requiriéndose un restablecimiento de fábrica para restaurar la función del servidor web auxiliar. • http://www.securityfocus.com/bid/95302 https://ics-cert.us-cert.gov/advisories/ICSA-16-336-06 •

CVSS: 7.3EPSS: 0%CPEs: 20EXPL: 0

An issue was discovered in Rockwell Automation Allen-Bradley MicroLogix 1100 controller 1763-L16AWA, Series A and B, Version 14.000 and prior versions; 1763-L16BBB, Series A and B, Version 14.000 and prior versions; 1763-L16BWA, Series A and B, Version 14.000 and prior versions; and 1763-L16DWD, Series A and B, Version 14.000 and prior versions. User credentials are sent to the web server in clear text, which may allow an attacker to discover the credentials if they are able to observe traffic between the web browser and the server. Ha sido descubierto un problema en controlador Rockwell Automation Allen-Bradley MicroLogix 1100, 1763-L16AWA, 1763-L16AWA, Series A y B, Versión 14.000 y versiones anteriores; 1763-L16BBB, Series A y B, Versión 14.000 y versiones anteriores; 1763-L16BWA, Series A y B, Versión 14.000 y versiones anteriores; y 1763-L16DWD, Series A y B, Versión 14.000 y versiones anteriores. Las credenciales de usuario son enviadas al servidor web en texto plano, lo que puede permitir a un atacante descubrir las credenciales si son capaces de observar el tráfico entre el navegador web y el servidor. • http://www.securityfocus.com/bid/95302 https://ics-cert.us-cert.gov/advisories/ICSA-16-336-06 •

CVSS: 10.0EPSS: 0%CPEs: 9EXPL: 0

Stack-based buffer overflow on Rockwell Automation Allen-Bradley MicroLogix 1100 devices A through 15.000 and B before 15.002 allows remote attackers to execute arbitrary code via a crafted web request. Desbordamiento de buffer basado en pila en dispositivos Rockwell Automation Allen-Bradley MicroLogix 1100 A hasta la versión 15.000 y B anteriores a 15.002 permite a atacantes remotos ejecutar código arbitrario a través de una petición web manipulada. • http://www.securitytracker.com/id/1034861 https://ics-cert.us-cert.gov/advisories/ICSA-16-026-02 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •