CVE-2016-0868
https://notcve.org/view.php?id=CVE-2016-0868
Stack-based buffer overflow on Rockwell Automation Allen-Bradley MicroLogix 1100 devices A through 15.000 and B before 15.002 allows remote attackers to execute arbitrary code via a crafted web request. Desbordamiento de buffer basado en pila en dispositivos Rockwell Automation Allen-Bradley MicroLogix 1100 A hasta la versión 15.000 y B anteriores a 15.002 permite a atacantes remotos ejecutar código arbitrario a través de una petición web manipulada. • http://www.securitytracker.com/id/1034861 https://ics-cert.us-cert.gov/advisories/ICSA-16-026-02 • CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer •
CVE-2014-5410
https://notcve.org/view.php?id=CVE-2014-5410
The DNP3 feature on Rockwell Automation Allen-Bradley MicroLogix 1400 1766-Lxxxxx A FRN controllers 7 and earlier and 1400 1766-Lxxxxx B FRN controllers before 15.001 allows remote attackers to cause a denial of service (process disruption) via malformed packets over (1) an Ethernet network or (2) a serial line. La caracteristica DNP3 en los controladores Rockwell Automation Allen-Bradley MicroLogix 1400 1766-Lxxxxx A FRN 7 y anteriores y 1400 1766-Lxxxxx B FRN anterior a 15.001 permite a atacantes remotos causar una denegación de servicio (interrupción del proceso) a través de paquetes malformados sobre (1) una red Ethernet o (2) una línea de seriales. • https://ics-cert.us-cert.gov/advisories/ICSA-14-254-02 • CWE-399: Resource Management Errors •
CVE-2012-4690
https://notcve.org/view.php?id=CVE-2012-4690
Rockwell Automation Allen-Bradley MicroLogix controller 1100, 1200, 1400, and 1500; SLC 500 controller platform; and PLC-5 controller platform, when Static status is not enabled, allow remote attackers to cause a denial of service via messages that trigger modification of status bits. Controlador Rockwell Automation Allen-Bradley MicroLogix v1100, v1200, v1400 y v1500; plataforma de controladores SLC 500 y PLC-5, cuando el estado Static no está activado, permite a atacantes remotos provocar una denegación de servicio a través de mensajes que desencadenan la modificación de bits de estado. • http://ics-cert.us-cert.gov/advisories/ICSA-12-342-01A http://www.us-cert.gov/control_systems/pdf/ICSA-12-342-01.pdf https://rockwellautomation.custhelp.com/app/answers/detail/a_id/511407 • CWE-16: Configuration •
CVE-2009-3739
https://notcve.org/view.php?id=CVE-2009-3739
Multiple unspecified vulnerabilities on the Rockwell Automation AB Micrologix 1100 and 1400 controllers allow remote attackers to obtain privileged access or cause a denial of service (halt) via unknown vectors. Múltiples vulnerabilidades sin especificar en Rockwell Automation AB Micrologix 1100 y 1400 controllers permite a atacantes remotos obtener privilegios de acceso o provocar una denegación de servicio (parada) a través de vectores desconocidos. • http://www.securityfocus.com/archive/1/508946/100/0/threaded •