Page 2 of 7 results (0.002 seconds)

CVSS: 9.8EPSS: 0%CPEs: 20EXPL: 0

Rockwell Automation Studio 5000 Logix Designer Versions 21 and later, and RSLogix 5000 Versions 16 through 20 use a key to verify Logix controllers are communicating with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer Versions 21 and later and RSLogix 5000: Versions 16 through 20 are vulnerable because an unauthenticated attacker could bypass this verification mechanism and authenticate with Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer versiones 21 y posteriores, y RSLogix 5000 versiones 16 hasta 20, usan una clave para verificar que los controladores Logix se estén comunicando con Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550, 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800. Rockwell Automation Studio 5000 Logix Designer versiones 21 y posteriores y RSLogix 5000: Versiones 16 hasta 20, son vulnerables porque un atacante no autenticado podría pasar por alto este mecanismo de comprobación y autenticarse con Rockwell Automation CompactLogix 1768, 1769, 5370, 5380, 5480: ControlLogix 5550 , 5560, 5570, 5580; DriveLogix 5560, 5730, 1794-L34; Compact GuardLogix 5370, 5380; GuardLogix 5570, 5580; SoftLogix 5800 • https://us-cert.cisa.gov/ics/advisories/icsa-21-056-03 • CWE-522: Insufficiently Protected Credentials •

CVSS: 10.0EPSS: 0%CPEs: 101EXPL: 0

An issue was discovered in Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.00 through 21.00 (excluding all firmware versions prior to FRN 16.00, which are not affected). By sending malformed common industrial protocol (CIP) packet, an attacker may be able to overflow a stack-based buffer and execute code on the controller or initiate a nonrecoverable fault resulting in a denial of service. Ha sido descubierto un problema en Rockwell Automation Logix5000 Programmable Automation Controller FRN 16.00 a 21.00 (excluyendo todas las versiones de firmware anteriores a FRN 16.00, que no se ven afectadas). Al enviar un paquete de protocolo industrial común (CIP) malformado, un atacante puede realizar un desbordamiento de búfer basado en pila y ejecutar código en el controlador o iniciar un fallo irrecuperable que da como resultado una denegación de servicio. • http://www.securityfocus.com/bid/95304 https://ics-cert.us-cert.gov/advisories/ICSA-16-343-05 • CWE-787: Out-of-bounds Write •